Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
TD-020SENSOR CURRENT SWITCH 20A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 20A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-025SENSOR CURRENT SWITCH 25A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 25A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-030SENSOR CURRENT SWITCH 30A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 30A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-035SENSOR CURRENT SWITCH 35A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 35A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-040SENSOR CURRENT SWITCH 40A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 40A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-045SENSOR CURRENT SWITCH 45A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 45A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-050SENSOR CURRENT SWITCH 50A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 50A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-055SENSOR CURRENT SWITCH 55A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 55A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-060SENSOR CURRENT SWITCH 60A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 60A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-065SENSOR CURRENT SWITCH 65A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 65A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-070SENSOR CURRENT SWITCH 70A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 70A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-080SENSOR CURRENT SWITCH 80A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 80A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-085SENSOR CURRENT SWITCH 85A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 85A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-090SENSOR CURRENT SWITCH 90A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 90A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-100SENSOR CURRENT SWITCH 100A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 100A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-120SENSOR CURRENT SWITCH 120A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 120A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
TD-125SENSOR CURRENT SWITCH 125A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 125A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
F01P050S05SENSOR CURRENT FLUX GATE 50A AC |
0 |
|
|
F01P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | 300kHz | ±1% | ±1.7% | 5V | 0.3µs | 55mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F02P050S05SENSOR CURRENT FLUX GATE 50A AC |
0 |
|
|
F02P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | 300kHz | ±1% | ±0.9% | 5V | 0.3µs | 55mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
L37S100D15MSENSOR |
0 |
|
|
L37S D155 | Module | Tray | Active | DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | - | ±1% | - | 15V | 3µs | 20mA | -40°C ~ 85°C | - | - | Unidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.