Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CAS 25-NP/SP1TRANSDUCER |
0 |
|
|
CASR | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Voltage | 25mV/A | DC ~ 300kHz | ±0.1% | ±0.8% | 4.75V ~ 5.25V | 300ns | - | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
CAS 15-NP/SP1TRANSDUCER |
0 |
|
|
CASR | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Voltage | 41.67mV/A | DC ~ 300kHz | ±0.1% | ±0.8% | 4.75V ~ 5.25V | 300ns | - | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
L03S800D15WJCURRENT SENSOR (800A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 800A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
L03S800D15WMCURRENT SENSOR (800A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 800A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -20°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
L07P003D15SENSOR CURRENT HALL 3A AC/DC |
0 |
|
|
L07P | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 3A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P005D15SENSOR CURRENT HALL 5A AC/DC |
0 |
|
|
L07P | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 5A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P010D15SENSOR CURRENT HALL 10A AC/DC |
0 |
|
|
L07P | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P015D15SENSOR CURRENT HALL 15A AC/DC |
0 |
|
|
L07P | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
L07P020D15SENSOR CURRENT HALL 20A AC/DC |
0 |
|
|
L07P | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 20A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P025D15SENSOR CURRENT HALL 25A AC/DC |
0 |
|
|
L07P | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P030D15SENSOR CURRENT HALL 30A AC/DC |
0 |
|
|
L07P | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 30A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L32P050S05FSSENSOR CURRENT HALL 50A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L31S600S05FSSENSOR CURRENT HALL 600A AC/DC |
0 |
|
|
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CASR 25-NP/SP1TRANSDUCER |
0 |
|
|
CASR | Module | Bulk | Active | AC/DC | Closed Loop | 25A | 1 | Voltage | 25mV/A | DC ~ 300kHz | ±0.1% | ±0.8% | 4.75V ~ 5.25V | 300ns | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
CASR 15-NP/SP1TRANSDUCER |
0 |
|
|
CASR | Module | Bulk | Active | AC/DC | Closed Loop | 15A | 1 | Voltage | 41.67mV/A | DC ~ 300kHz | ±0.1% | ±0.8% | 4.75V ~ 5.25V | 300ns | - | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
CASR 6-NP/SP3TRANSDUCER |
0 |
|
|
CASR | Module | Bulk | Active | AC/DC | Closed Loop | 6A | 1 | Voltage | 104.2mV/A | DC ~ 300kHz | ±0.1% | ±0.8% | 4.75V ~ 5.25V | 300ns | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
|
HLSR 40-SMSENSOR CURRENT HALL 40A AC/DC |
0 |
|
|
HLSR-SM | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 40A | 1 | Ratiometric, Voltage | 20mV/A | 400kHz | ±0.5% | ±1% | 5V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Surface Mount | - |
|
|
F01P015S05SENSOR CURRENT FLUX GATE 15A AC |
0 |
|
|
F01P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±1% | ±1.9% | 5V | 0.3µs | 30mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F02P015S05SENSOR CURRENT FLUX GATE 15A AC |
0 |
|
|
F02P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±1% | ±1.2% | 5V | 0.3µs | 30mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
L32P100S05FSSENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.