Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HXS 10-NP/SP3SENSORS |
0 |
|
|
HXS | Module | Bulk | Not For New Designs | AC/DC | Hall Effect | 10A, 20A (Selectable) | 1 | Analog Voltage | 625mV/A | DC ~ 50kHz | ±0.5% | ±1% | 5V | 3µs | 19mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
|
F01P006S05LSENSOR |
0 |
|
|
F01P | Module | Tray | Active | AC/DC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±1% | ±2.5% | 5V | 0.3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F03P006S05DSENSOR |
0 |
|
|
F03P | Module | Tray | Active | AC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±0.1% | - | 4.75V ~ 5.25V | 0.3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F02P006S05LSENSOR |
0 |
|
|
F02P | Module | Tray | Active | AC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±1% | ±1.7% | 5V | 0.3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
L31S050S05FSSENSOR CURRENT HALL 50A AC/DC |
0 |
|
|
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L03S400D15WJCURRENT SENSOR (400A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 400A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
|
S22P015S05SENSOR CURRENT HALL 15A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.2% | - | 5V | 1µs | 12.5mA | -10°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CSLH3A9SENSOR CURRENT HALL 9A AC/DC |
0 |
|
|
CSLH | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 9A | 1 | Ratiometric, Voltage | 282mV/N | - | - | - | 4.5V ~ 10.5V | 3µs | 30mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L03S300D15WMSENSOR |
0 |
|
|
L03S | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
S23P50/100D15M2CURRENT SENSOR (50A/100A; 15V) |
0 |
|
|
S23P M2 | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 50A, 100A | 1 | Ratiometric, Current | - | - | ±0.15% | ±0.25% | ±12V ~ 15V | 500ns | 16mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
|
S22P025S05SENSOR CURRENT HALL 25A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.2% | - | 5V | 1µs | 12.5mA | -10°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L18P005D15SENSOR CURRENT HALL 5A AC/DC |
1 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 5A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L31S100S05FSSENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
T60404N4647X161CURRENT SENSOR, 50A, PRI OPEN, 5 |
0 |
|
|
- | Module, Single Pass Through | Box | Active | AC/DC | Closed Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.1% | ±1% | 4.75V ~ 5.25V | 1µs | 16mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
CASR 25-NP/SP3TRANSDUCER |
0 |
|
|
CASR | Module | Bulk | Active | AC/DC | Closed Loop | 25A | 1 | Voltage | 25mV/A | DC ~ 300kHz | ±0.1% | ±0.8% | 4.75V ~ 5.25V | 300ns | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
CASR 15-NP/SP3TRANSDUCER |
0 |
|
|
CASR | Module | Bulk | Active | AC/DC | Closed Loop | 15A | 1 | Voltage | 41.67mV/A | DC ~ 300kHz | ±0.1% | ±0.8% | 4.75V ~ 5.25V | 300ns | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
L03S500D15WJCURRENT SENSOR (500A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
HLSR 16-PW-010TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Open Loop | 16A | 1 | Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HLSR 32-PW-010TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Open Loop | 16A | 1 | Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HLSR 50-PW-010TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Open Loop | 16A | 1 | Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.