Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CQ3202CORELESS CURENT SENSOR / 20A W/S |
0 |
|
|
- | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 21.1A | 1 | Ratiometric, Voltage | 60mV/A | - | - | ±1.3% | 3.3V | 0.5µs | 6.2mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
CQ3203CORELESS CURENT SENSOR / 20A W/S |
0 |
|
|
- | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 35.7A | 1 | Ratiometric, Voltage | 37mV/A | - | - | ±1.3% | 3.3V | 0.5µs | 6.2mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
CQ3204CORELESS CURENT SENSOR / 20A W/S |
0 |
|
|
- | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 44A | 1 | Ratiometric, Current | 30mV/A | 1MHz | ±0.6% | ±1.2% | 2.7V ~ 3.63V | 0.5µs | 9.6mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
CQ320ACORELESS CURENT SENSOR / 20A W/S |
0 |
|
|
- | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 29.3A | 1 | Ratiometric, Voltage | 45mV/A | - | - | ±1.3% | 3.3V | 0.5µs | 6.2mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
|
L18P060S05SENSOR CURRENT HALL 60A AC/DC |
0 |
|
|
L18PXXXS05 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 60A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L18P050S12SENSOR CURRENT HALL 50A AC/DC |
0 |
|
|
L18PXXXS12 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 12V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
MLX91206LDC-CAH-003-RESENSOR CURRENT HALL 25MT AC/DC |
0 |
|
|
Triaxis® | 8-SOIC (0.154", 3.90mm Width) | Tape & Reel (TR) | Active | AC/DC | Hall Effect, Open Loop | 25mT | 1 | Ratiometric, Voltage or PWM (Selectable) | 110mV/mT | DC ~ 90kHz | ±0.5% | ±1% | 4.5V ~ 5.5V | 8µs | 12mA | -40°C ~ 150°C | - | - | Bidirectional | Surface Mount | 8-SOIC |
|
L18P060S12SENSOR CURRENT HALL 60A AC/DC |
0 |
|
|
L18PXXXS12 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 60A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 12V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
HLSR 32-SM/SP33SENSOR CURRENT HALL 32A AC/DC |
0 |
|
|
HLSR-SM/SP33 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 32A | 1 | Ratiometric, Voltage | 14.375mV/A | 400kHz | ±0.5% | ±1% | 3.3V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Surface Mount | - |
|
|
HLSR 40-SM/SP33SENSOR CURRENT HALL 40A AC/DC |
0 |
|
|
HLSR-SM/SP33 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 40A | 1 | Ratiometric, Voltage | 11.5mV/A | 400kHz | ±0.5% | ±1% | 3.3V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Surface Mount | - |
|
T60404N4647X460CURRENT SENSOR, 50A, 3 PRI PINS, |
0 |
|
|
- | 10-DIP Module | Box | Active | AC/DC | Closed Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 1µs | 16mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
T60404N4646X6534646X653 |
0 |
|
|
- | 9-DIP Module | Box | Active | AC/DC | Closed Loop | 6A | 1 | Voltage | - | DC ~ 100kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
T60404N4646X6524646X652 |
0 |
|
|
- | 9-DIP Module | Box | Active | AC/DC | Closed Loop | 15A | 1 | Voltage | - | DC ~ 100kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
T60404N4647X461CURRENT SENSOR, 100A, 3 PRI PINS |
0 |
|
|
- | 10-DIP Module | Box | Active | AC/DC | Closed Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 1µs | 16mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
T60404N4646X6624646X662 |
0 |
|
|
- | 10-DIP Module | Box | Active | AC/DC | Closed Loop | 15A | 1 | Voltage | - | DC ~ 200kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
ZMC10DSENSOR CURRENT MR 10A AC/DC |
0 |
|
|
- | 14-DIP (0.400", 10.16mm) | Bulk | Obsolete | AC/DC | Magnetoresistive, Open Loop | 10A | 1 | Ratiometric, Voltage | - | 100kHz | - | - | 12V | - | 20mA | -25°C ~ 100°C | - | - | Bidirectional | Through Hole | DIL-14 |
|
L03S050D15WJCURRENT SENSOR (50A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
L03S050D15WMCURRENT SENSOR (50A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -20°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
S22P006S05M2SENSOR CURRENT HALL 6A AC/DC |
0 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.2% | - | 5V | 1µs | 12.5mA | -10°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L08P500D15IPVWCURRENT SENSOR (500A; 15V) |
0 |
|
|
- | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 8µs | 20mA | -40°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.