Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
L12P025D15SENSOR CURRENT HALL 25A AC/DC |
0 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
T60404N4646X6644646X664 |
0 |
|
|
- | 10-DIP Module | Box | Active | AC/DC | Closed Loop | 50A | 1 | Voltage | - | DC ~ 200kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L03S100D15WJCURRENT SENSOR (100A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
S22P015S05M2SENSOR CURRENT HALL 15A AC/DC |
0 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.2% | - | 5V | 1µs | 12.5mA | -10°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
T60404N4648X400CURRENT SENSOR, 25A, 3 PRI PINS, |
0 |
|
|
- | 9-DIP Module | Box | Active | AC/DC | Closed Loop | 25A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.1% | ±0.5% | ±11.4V ~ 15.75V | 500µs | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
L07P003S05SENSOR CURRENT HALL 3A AC/DC |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 3A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
HXS 20-NP/SP7SENSORS |
0 |
|
|
HXS | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 20A | 1 | Analog Voltage | 625mV/A | DC ~ 50kHz | ±0.5% | ±1% | 5V | 5µs | 19mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
HXS 20-NP/SP30SENSORS |
0 |
|
|
HXS | Module | Bulk | Not For New Designs | AC/DC | Hall Effect | 20A | 1 | Analog Voltage | 625mV/A | DC ~ 50kHz | ±0.5% | ±1% | 5V | 3µs | 19mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
S22P025S05M2SENSOR CURRENT HALL 25A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.2% | - | 5V | 1µs | 12.5mA | -10°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L03S200D15WJCURRENT SENSOR (200A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
LA01P170S05SENSOR |
0 |
|
|
LA01P | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 170A | 1 | Ratiometric, Voltage | 12.5mV/A | DC ~ 400kHz | ±1% | ±1% | 4.5V ~ 5.5V | 1µs | 10mA | -40°C ~ 90°C | - | - | Bidirectional | Through Hole | - |
|
L03S100D15WMSENSOR |
0 |
|
|
L03S | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
L07P010S05SENSOR CURRENT HALL 10A AC/DC |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
HLSR 100-P/SP10TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Voltage | 8mV/A | DC ~ 90kHz | ±0.5% | ±3.8% | 4.5V ~ 5.5V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
HLSR 80-P/SP10TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 80A | 1 | Voltage | 10mV/A | DC ~ 90kHz | ±0.5% | ±3.8% | 4.5V ~ 5.5V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
L03S300D15WJCURRENT SENSOR (300A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
|
S22P006S05SENSOR CURRENT HALL 6A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.2% | - | 5V | 1µs | 12.5mA | -10°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HLSR 20-P/SP1TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 20A | 1 | Voltage | 23mV/A | DC ~ 240kHz | ±0.5% | ±1% | 4.5V ~ 5.5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
L03S200D15WMSENSOR |
0 |
|
|
L03S | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
CKSR 25-NP/SP3TRANSDUCER |
0 |
|
|
CKSR | Module | Bulk | Active | AC/DC | Closed Loop | 25A | 1 | Voltage | 25mV/A | DC ~ 300kHz | ±0.1% | ±0.8% | 4.75V ~ 5.25V | 300ns | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.