Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HLSR 50-PW-080TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Open Loop | 16A | 1 | Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HLSR 40-PW-010TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Open Loop | 16A | 1 | Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
T60404N4647X160CURRENT SENSOR,100A, PRI OPEN, 5 |
0 |
|
|
- | Module, Single Pass Through | Box | Active | AC/DC | Closed Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.1% | ±1% | 4.75V ~ 5.25V | 1µs | 16mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
|
F03P015S05SENSOR CURRENT FLUX GATE 15A AC |
0 |
|
|
F03P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.7mV/A | 300kHz | ±1% | ±1.2% | 5V | 0.3µs | 30mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
L31S200S05FSSENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L03S400D15WMSENSOR |
0 |
|
|
L03S | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
26461INA226AIDGSR, I2C interface |
10 |
|
|
- | Module | Bulk | Active | AC/DC | Current Sensor | 820mA | 1 | I2C | - | - | - | ±0.1% | 2.7V ~ 5.5V | - | 330µA | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | Module |
|
L03S600D15WJCURRENT SENSOR (600A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 600A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
L07P010D15SSENSOR CURRENT HALL |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 10A | 2 | Ratiometric, Voltage | - | - | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P005D15SSENSOR CURRENT HALL |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 5A | 2 | Ratiometric, Voltage | - | - | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P030D15SSENSOR CURRENT HALL |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 30A | 2 | Ratiometric, Voltage | - | - | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P003D15SSENSOR CURRENT HALL |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 3A | 2 | Ratiometric, Voltage | - | - | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P020D15SSENSOR CURRENT HALL |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 20A | 2 | Ratiometric, Voltage | - | - | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P015D15SSENSOR CURRENT HALL |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 15A | 2 | Ratiometric, Voltage | - | - | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P025D15SSENSOR CURRENT HALL |
0 |
|
|
L07P | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 25A | 2 | Ratiometric, Voltage | - | - | ±1% | - | ±15V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L31S300S05FSSENSOR CURRENT HALL 300A AC/DC |
0 |
|
|
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
S23P50/100D15M1SENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.15% | ±0.25% | ±12V ~ 15V | 0.5µs | 50mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L03S500D15WMSENSOR |
0 |
|
|
L03S | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
TLI4970D025T5XUMA1SENSOR CURRENT HALL 25A 8TISON |
0 |
|
|
- | 8-PowerTDFN | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Differential | 25A | 1 | SPI | - | DC ~ 18kHz | ±1.6% | ±3.5% | 3.1V ~ 3.5V | 57µs | 20mA | -40°C ~ 85°C | Automotive | AEC-Q100 | Unidirectional | Surface Mount | PG-TISON-8-1 |
|
T60404N4646X4134646X413 |
0 |
|
|
- | 9-DIP Module | Box | Active | AC/DC | Closed Loop | 100A | 1 | Current | - | DC ~ 200kHz | ±0.1% | ±0.5% | ±11.4V ~ 15.75V | 500ns | 18.5mA | -40°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.