| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AK3103IC CORELESS CURRENT SENSE 14SOP |
0 |
|
|
- | 24-PowerLSSOP (0.220", 5.60mm Width), 14 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 35A | 1 | Ratiometric, Voltage | 60mV/A | 210kHz | ±0.6% | ±1.5% | 4.5V ~ 5.5V | 2µs | 20mA | -40°C ~ 90°C | - | - | Unidirectional | Surface Mount | 24-SMD |
|
L03S050D15SENSOR CURRENT HALL 50A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -20°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L32P150S05FSSENSOR CURRENT HALL 150A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HO 15-NSM/SP33-1000SENSOR CURRENT HALL 15A AC/DC |
0 |
|
|
HO-NSM-0000 | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 250kHz | ±0.5% | ±1% | 3.3V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Surface Mount | - |
|
L03S100D15SENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -20°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
F01P025S05SENSOR CURRENT FLUX GATE 25A AC |
0 |
|
|
F01P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | 300kHz | ±1% | ±1.8% | 5V | 0.3µs | 35mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F02P025S05SENSOR CURRENT FLUX GATE 25A AC |
0 |
|
|
F02P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | 300kHz | ±1% | ±1% | 5V | 0.3µs | 35mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
L32P200S05FSSENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L03S200D15SENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -20°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L03S300D15SENSOR CURRENT HALL 300A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -20°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L32P300S05FSSENSOR CURRENT HALL 300A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HLSR 120-P/SP10TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Open Loop | 120A | 1 | Voltage | 6.67mV/A | 90kHz | ±0.5% | ±1% | 4.5V ~ 5.5V | 2.5µs | 25mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
L03S400D15SENSOR CURRENT HALL 400A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -20°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L37S050D15MSENSOR |
0 |
|
|
L37S D155 | Module | Tray | Active | DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | - | - | ±1% | - | 15V | 3µs | 20mA | -40°C ~ 85°C | - | - | Unidirectional | Chassis Mount | - |
|
L37S050S05JCURRENT SENSOR (50A; +5V) |
0 |
|
|
L37S S05 | Module, Single Pass Through | Tray | Active | DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | - | 4.75V ~ 5.25V | 5µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L37S050D15JCURRENT SENSOR (50A; 15V) |
0 |
|
|
L37S D15 | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 3µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L05Z800S15SENSOR CURRENT HALL 800A AC/DC |
0 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 800A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 10µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
L03S500D15SENSOR CURRENT HALL 500A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -20°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L32P400S05FSSENSOR CURRENT HALL 400A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
|
TD-015SENSOR CURRENT SWITCH 15A DC |
0 |
|
|
TD | Module | Bulk | Obsolete | DC | Current Switch | 15A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.