Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
L37S100D15JCURRENT SENSOR (100A; 15V) |
0 |
|
|
L37S D15 | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 3µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L37S100S05JCURRENT SENSOR (100A; +5V) |
0 |
|
|
L37S S05 | Module, Single Pass Through | Tray | Active | DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | - | 4.75V ~ 5.25V | 5µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CASR 50-NP/SP1TRANSDUCER |
0 |
|
|
CASR | Module | Bulk | Active | AC/DC | Closed Loop | 50A | 1 | Voltage | 12.5mV/A | DC ~ 300kHz | ±0.1% | ±0.8% | 4.75V ~ 5.25V | 300ns | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
L32P100S05BFSSENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L03S600D15SENSOR CURRENT HALL 600A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -20°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
F03P025S05DSENSOR |
0 |
|
|
F03P | Module | Tray | Active | AC | Flux Gate, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | 300kHz | ±0.1% | - | 4.75V ~ 5.25V | 0.3µs | 35mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
HMS 20-PSENSOR CURRENT HALL 20A AC/DC |
0 |
|
|
HMS | Module | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 20A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | 5V | 5µs | 19mA | -40°C ~ 85°C | - | - | Bidirectional | Surface Mount | - |
|
L37S200D15MSENSOR |
0 |
|
|
L37S D155 | Module | Tray | Active | DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | - | ±1% | - | 15V | 3µs | 20mA | -40°C ~ 85°C | - | - | Unidirectional | Chassis Mount | - |
|
L37S200S05JCURRENT SENSOR (200A; +5V) |
0 |
|
|
L37S S05 | Module, Single Pass Through | Tray | Active | DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | - | 4.75V ~ 5.25V | 5µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L37S200D15JCURRENT SENSOR (200A; 15V) |
0 |
|
|
L37S D15 | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 3µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L32P050S05BFSSENSOR CURRENT HALL 50A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HXN 15-PSENSORS |
0 |
|
|
HXN | Module | Bulk | Not For New Designs | AC/DC | Hall Effect | 15A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
HXN 05-PSENSORS |
0 |
|
|
HXN | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 5A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HXN 03-PSENSORS |
0 |
|
|
HXN | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 3A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HXN 10-PSENSORS |
0 |
|
|
HXN | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 10A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HXN 20-PSENSORS |
0 |
|
|
HXN | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 20A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HXN 25-PSENSORS |
0 |
|
|
HXN | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 25A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L37S300S05JCURRENT SENSOR (300A; +5V) |
0 |
|
|
L37S S05 | Module, Single Pass Through | Tray | Active | DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | - | 4.75V ~ 5.25V | 5µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L37S300D15JCURRENT SENSOR (300A; 15V) |
0 |
|
|
L37S D15 | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 3µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
|
F03P050S05SENSOR CURRENT FLUX GATE 50A AC |
0 |
|
|
F03P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | 300kHz | ±1% | ±0.9% | 5V | 0.3µs | 55mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.