| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
9001-125SENSOR CURRENT SWITCH 125A DC |
0 |
|
|
9001 | Module, Single Board Pass Through | Bulk | Obsolete | DC | Current Switch | 125A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
9001-150SENSOR CURRENT SWITCH 150A DC |
0 |
|
|
9001 | Module, Single Board Pass Through | Bulk | Obsolete | DC | Current Switch | 150A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
L07P005S05SENSOR CURRENT HALL 5A AC/DC |
0 |
|
|
L07P | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 5A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L37S600D15MSENSOR |
0 |
|
|
L37S D155 | Module | Tray | Active | DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | - | ±1% | - | 15V | 3µs | 20mA | -40°C ~ 85°C | - | - | Unidirectional | Chassis Mount | - |
|
L37S600S05JCURRENT SENSOR (600A; +5V) |
0 |
|
|
L37S S05 | Module, Single Pass Through | Tray | Active | DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | - | 4.75V ~ 5.25V | 5µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L37S600D15JCURRENT SENSOR (600A; 15V) |
0 |
|
|
L37S D15 | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 3µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
|
S25P050D15XSENSOR CURRENT HALL 50A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.15% | ±0.5% | ±12V ~ 15V | 1µs | 16mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
S25P100D15XSENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.15% | ±0.5% | ±12V ~ 15V | 1µs | 16mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HX 06-PSENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 6A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HX 02-PSENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 2A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HX 03-P/SP2SENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 3A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±12V ~ 15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
HX 15-P/SP2SENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 15A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±12V ~ 15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
HX 10-P/SP2SENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 10A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±12V ~ 15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
HX 05-P/SP2SENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 5A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±12V ~ 15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
HX 10-NPSENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 10A, 20A (Selectable) | 1 | Analog Voltage | - | DC ~ 50kHz | ±0.1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HX 05-NPSENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 5A, 10A (Selectable) | 1 | Analog Voltage | - | DC ~ 50kHz | ±0.1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HO 40-NP/SP33-1106SENSORS |
0 |
|
|
HO | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 40A | 1 | Voltage | 11.5mV/A | 350kHz | ±0.75% | ±1.25% | 3.14V ~ 3.46V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
HAFS 400-S/SP8TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HAFS 600-S/SP8TRANSDUCER |
0 |
|
|
HAFS | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect | 600A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | 5V | 5µs | 19mA | -40°C ~ 125°C | - | - | - | Chassis Mount | - |
|
|
S25P100D15YSENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
S25PXXXD15Y | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.15% | ±0.5% | ±12V ~ 15V | 1µs | 16mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.