Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
L01Z500S05SENSOR CURRENT HALL 500A AC/DC |
0 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 10µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L37S400D15MSENSOR |
0 |
|
|
L37S D155 | Module | Tray | Active | DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | - | ±1% | - | 15V | 3µs | 20mA | -40°C ~ 85°C | - | - | Unidirectional | Chassis Mount | - |
|
L37S400D15JCURRENT SENSOR (400A; 15V) |
0 |
|
|
L37S D15 | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 3µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L37S400S05JCURRENT SENSOR (400A; +5V) |
0 |
|
|
L37S S05 | Module, Single Pass Through | Tray | Active | DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | - | 4.75V ~ 5.25V | 5µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L07P007S05SENSOR CURRENT HALL 7A AC/DC |
0 |
|
|
L07P | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 7A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P015S05SENSOR CURRENT HALL 15A AC/DC |
0 |
|
|
L07P | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P020S05SENSOR CURRENT HALL 20A AC/DC |
0 |
|
|
L07P | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 20A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P025S05SENSOR CURRENT HALL 25A AC/DC |
0 |
|
|
L07P | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P030S05SENSOR CURRENT HALL 30A AC/DC |
0 |
|
|
L07P | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 30A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L07P040S05SENSOR CURRENT HALL 40A AC/DC |
0 |
|
|
L07P | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 40A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 30mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L37S500D15MSENSOR |
0 |
|
|
L37S D155 | Module | Tray | Active | DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | - | ±1% | - | 15V | 3µs | 20mA | -40°C ~ 85°C | - | - | Unidirectional | Chassis Mount | - |
|
L37S500S05JCURRENT SENSOR (500A; +5V) |
0 |
|
|
L37S S05 | Module, Single Pass Through | Tray | Active | DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | - | 4.75V ~ 5.25V | 5µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L37S500D15JCURRENT SENSOR (500A; 15V) |
0 |
|
|
L37S D15 | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 3µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L37S500S05MCURRENT SENSOR (500A; +5V) |
0 |
|
|
L37S S05 | Module, Single Pass Through | Tray | Active | DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | - | 4.75V ~ 5.25V | 5µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HXS 50-NP/SP6SENSORS |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LESR 15-NP/SP1SENSORS |
0 |
|
|
LESR | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Voltage | 41.67mV/A | DC ~ 300kHz | ±0.1% | ±0.9% | 4.75V ~ 5.25V | 400ns | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
LESR 6-NP/SP1SENSORS |
0 |
|
|
LESR | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Voltage | 104.2mV/A | DC ~ 300kHz | ±0.1% | ±1.5% | 4.75V ~ 5.25V | 400ns | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
LESR 25-NP/SP1SENSORS |
0 |
|
|
LESR | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Voltage | 25mV/A | DC ~ 300kHz | ±0.1% | ±0.9% | 4.75V ~ 5.25V | 400ns | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
9001-050SENSOR CURRENT SWITCH 50A DC |
0 |
|
|
9001 | Module, Single Board Pass Through | Bulk | Obsolete | DC | Current Switch | 50A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
9001-100SENSOR CURRENT SWITCH 100A DC |
0 |
|
|
9001 | Module, Single Board Pass Through | Bulk | Obsolete | DC | Current Switch | 100A | 1 | Open Collector | - | - | - | - | 3.8V ~ 24V | 1µs | 10mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.