Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HO 80-NPW-0100SENSORS |
0 |
|
|
HO | Module | Bulk | Active | AC/DC | Open Loop | 80A | 1 | Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 120-NP/SP33-1106SENSORS |
0 |
|
|
HO | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 120A | 1 | Voltage | 3.83mV/A | 350kHz | ±0.5% | ±1.25% | 3.14V ~ 3.46V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
HX 50-P/SP14SENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect | 50A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
LA37S300S05KJCURRENT SENSOR (300A; 5V) -40 10 |
0 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 300A | 1 | Analog Voltage | 2.083mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 4µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S100S05KJCURRENT SENSOR (100A; 5V) -40 10 |
0 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 100A | 1 | Analog Voltage | 6.25mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 4µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S500S05KJCURRENT SENSOR (500A; 5V) -40 10 |
0 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 500A | 1 | Analog Voltage | 1.25mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 4µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S400S05KJCURRENT SENSOR (400A; 5V) -40 10 |
0 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 400A | 1 | Analog Voltage | 1.563mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 4µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S200S05KJCURRENT SENSOR (200A; 5V) -40 10 |
0 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 200A | 1 | Analog Voltage | 3.125mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 4µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S050S05KJCURRENT SENSOR (50A; 5V) -40 105 |
0 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 50A | 1 | Analog Voltage | 12.5mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 4µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S600S05KJCURRENT SENSOR (600A; 5V) -40 10 |
0 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 600A | 1 | Analog Voltage | 1.042mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 4µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
HX 12.5-P/SP31SENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 12.5A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1.5% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HX 10-P/SP31SENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 10A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1.5% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HAFS 200-S/SP8TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HX 05-P/SP31SENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 5A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1.5% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HX 15-NPSENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 15A, 30A (Selectable) | 1 | Analog Voltage | - | DC ~ 50kHz | ±0.1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
TL100-D1CCURRENT SENSOR 100A 1 CHANNEL HA |
5 |
|
|
TLx00-D1C | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 1µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
T60404N4647X261CURRENT SENSOR 100A, PRI OPEN, 5 |
0 |
|
|
- | 8-DIP Module | Box | Active | AC/DC | Closed Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 1µs | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
HO 250-P/SP606-1106SENSORS |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HX 06-P/SP31SENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 6A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1.5% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HAB 60-S/SP5CURRENT TRANSDUCER +/- 60A |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.