Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HX 50-P/SP2SENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 50A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±12V ~ 15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
HY 15-P/SP1Linear IC |
0 |
|
|
HY | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 15A | 1 | Analog Voltage | - | DC ~ 25kHz | ±1% | ±2% | 5V | 5µs | 10mA | -10°C ~ 75°C | - | - | Bidirectional | Through Hole | - |
|
HX 03-P/SP6SENSORS |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HX 50-P/SP9SENSORS |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
SCD03PUNSENSOR CURRENT HALL 3A DC |
0 |
|
|
SCD | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 3A | 1 | Ratiometric, Voltage | - | 50Hz/60Hz | ±0.5% | - | 5V | 7µs | 10mA | -10°C ~ 75°C | - | - | Unidirectional | - | - |
|
SCD10PUNSENSOR CURRENT HALL 10A DC |
0 |
|
|
SCD | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | 50Hz/60Hz | ±0.5% | - | 5V | 7µs | 10mA | -10°C ~ 75°C | - | - | Unidirectional | - | - |
|
SCD15PUNSENSOR CURRENT HALL 15A DC |
0 |
|
|
SCD | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 15A | 1 | Ratiometric, Voltage | - | 50Hz/60Hz | ±0.5% | - | 5V | 7µs | 10mA | -10°C ~ 75°C | - | - | Unidirectional | - | - |
|
SCD03PURSENSOR CURRENT HALL 3A AC |
0 |
|
|
SCD | Module | Bulk | Obsolete | AC | Hall Effect, Open Loop | 3A | 1 | Ratiometric, Voltage | - | 50Hz/60Hz | ±0.5% | - | 5V | 3µs | 25mA | -10°C ~ 75°C | - | - | Bidirectional | - | - |
|
SCD10PURSENSOR CURRENT HALL 10A AC |
0 |
|
|
SCD | Module | Bulk | Obsolete | AC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | 50Hz/60Hz | ±0.5% | - | 5V | 3µs | 25mA | -10°C ~ 75°C | - | - | Bidirectional | - | - |
|
SCD03PSNSENSOR CURRENT HALL 3A DC |
0 |
|
|
SCD | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 3A | 1 | Ratiometric, Voltage | - | 50Hz/60Hz | ±0.5% | - | 12V | 3µs | 25mA | -10°C ~ 75°C | - | - | Unidirectional | - | - |
|
SCD05PSNSENSOR CURRENT HALL 5A DC |
0 |
|
|
SCD | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 5A | 1 | Ratiometric, Voltage | - | 50Hz/60Hz | ±0.5% | - | 12V | 3µs | 25mA | -10°C ~ 75°C | - | - | Unidirectional | - | - |
|
SCD10PSNSENSOR CURRENT HALL 10A DC |
0 |
|
|
SCD | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | 50Hz/60Hz | ±0.5% | - | 12V | 3µs | 25mA | -10°C ~ 75°C | - | - | Unidirectional | - | - |
|
SCD15PSNSENSOR CURRENT HALL 15A DC |
0 |
|
|
SCD | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 15A | 1 | Ratiometric, Voltage | - | 50Hz/60Hz | ±0.5% | - | 12V | 3µs | 25mA | -10°C ~ 75°C | - | - | Unidirectional | - | - |
|
SCD20PSNSENSOR CURRENT HALL 20A DC |
0 |
|
|
SCD | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 20A | 1 | Ratiometric, Voltage | - | 50Hz/60Hz | ±0.5% | - | 12V | 3µs | 25mA | -10°C ~ 75°C | - | - | Unidirectional | - | - |
|
SCD03PSRSENSOR CURRENT HALL 3A AC |
0 |
|
|
SCD | Module | Bulk | Obsolete | AC | Hall Effect, Open Loop | 3A | 1 | Ratiometric, Voltage | - | 50Hz/60Hz | ±0.5% | - | 12V | 3µs | 25mA | -10°C ~ 75°C | - | - | Bidirectional | - | - |
|
SCD10PSRSENSOR CURRENT HALL 10A AC |
0 |
|
|
SCD | Module | Bulk | Obsolete | AC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | 50Hz/60Hz | ±0.5% | - | 12V | 3µs | 25mA | -10°C ~ 75°C | - | - | Bidirectional | - | - |
|
SCD20PSRSENSOR CURRENT HALL 20A AC |
0 |
|
|
SCD | Module | Bulk | Obsolete | AC | Hall Effect, Open Loop | 20A | 1 | Ratiometric, Voltage | - | 50Hz/60Hz | ±0.5% | - | 12V | 3µs | 25mA | -10°C ~ 75°C | - | - | Bidirectional | - | - |
|
HXS 10-NP/SP4SENSORS |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LAH 50-P/SP1SENSOR CURRENT 50A TH |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LA12-48V21SENSCURR MAGNETIC DIRECT MDCS 48 |
0 |
|
|
LA12 | Module | Bulk | Active | AC/DC | Hall Effect | 48A | - | Ratiometric, Voltage | - | - | - | - | 12V | - | - | -10°C ~ 75°C | - | - | - | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.