Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
L31S400S05FSSENSOR CURRENT HALL 400A AC/DC |
0 |
|
|
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L03S700D15WJCURRENT SENSOR (700A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 700A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
L03S700D15WMCURRENT SENSOR (700A; 15V) |
0 |
|
|
L03S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 700A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 10µs | 20mA | -20°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
|
F01P006S05SENSOR CURRENT FLUX GATE 6A AC |
0 |
|
|
F01P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±1% | ±2.5% | 5V | 0.3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F02P006S05SENSOR CURRENT FLUX GATE 6A AC |
0 |
|
|
F02P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±1% | ±1.7% | 5V | 0.3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F03P006S05SENSOR CURRENT FLUX GATE 6A AC |
0 |
|
|
F03P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±1% | ±1.7% | 5V | 0.3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F03P025S05SENSOR CURRENT FLUX GATE 25A AC |
0 |
|
|
F03P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | 300kHz | ±1% | ±1% | 5V | 0.3µs | 35mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
CKSR 50-NP/SP1TRANSDUCER |
0 |
|
|
CKSR | Module | Bulk | Active | AC/DC | Closed Loop | 50A | 1 | Voltage | 0.0125mV/A | DC ~ 300kHz | ±0.1% | ±1.2% | 4.75V ~ 5.25V | - | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
L03S600D15WMSENSOR |
0 |
|
|
L03S | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 20mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
L31S500S05FSSENSOR CURRENT HALL 500A AC/DC |
0 |
|
|
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
L10P003D15SENSOR CURRENT HALL 3A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 3A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L10P005D15SENSOR CURRENT HALL 5A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 5A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L10P015D15SENSOR CURRENT HALL 15A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L10P020D15SENSOR CURRENT HALL 20A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 20A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L10P025D15SENSOR CURRENT HALL 25A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L16P003D15SENSOR CURRENT HALL 3A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 3A | 1 | Ratiometric, Voltage | - | DC ~ 35kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L16P005D15SENSOR CURRENT HALL 5A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 5A | 1 | Ratiometric, Voltage | - | DC ~ 35kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L16P010D15SENSOR CURRENT HALL 10A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | DC ~ 35kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L16P015D15SENSOR CURRENT HALL 15A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 35kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
|
L16P025D15SENSOR CURRENT HALL 25A DC |
0 |
|
|
- | Module | Bulk | Obsolete | DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 35kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -10°C ~ 80°C | - | - | Unidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.