Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
L18P015S05SENSOR CURRENT HALL 15A AC/DC |
0 |
|
|
L18PXXXS05 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L18P010S12SENSOR CURRENT HALL 10A AC/DC |
0 |
|
|
L18PXXXS12 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 12V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
T60404M4645X6004645X600 |
0 |
|
|
- | 10-DIP Module | Box | Active | AC/DC | Closed Loop | 25A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.5% | - | 300ns | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L18P025S05SENSOR CURRENT HALL 25A AC/DC |
0 |
|
|
L18PXXXS05 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L18P020S12SENSOR CURRENT HALL 20A AC/DC |
0 |
|
|
L18PXXXS12 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 20A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 12V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
DVC DIN RAIL FIXING KITTRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
L18P030S05SENSOR CURRENT HALL 30A AC/DC |
0 |
|
|
L18PXXXS05 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 30A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L18P025S12SENSOR CURRENT HALL 25A AC/DC |
0 |
|
|
L18PXXXS12 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 12V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
L18P040S05SENSOR CURRENT HALL 40A AC/DC |
0 |
|
|
L18PXXXS05 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 40A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L18P030S12SENSOR CURRENT HALL 30A AC/DC |
0 |
|
|
L18PXXXS12 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 30A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 12V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L18P050S05SENSOR CURRENT HALL 50A AC/DC |
0 |
|
|
L18PXXXS05 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L18P040S12SENSOR CURRENT HALL 40A AC/DC |
0 |
|
|
L18PXXXS12 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 40A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 12V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
CQ3301SENSOR CURRENT HALL 35A AC/DC |
0 |
|
|
CQ | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 10.7A | 1 | Ratiometric, Voltage | 196mV/A | 1MHz | ±0.6% | ±0.5% | 4.5V ~ 5.5V | 0.5µs | 11mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
CQ3303SENSOR CURRENT HALL 20A AC/DC |
0 |
|
|
CQ | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 35A | 1 | Ratiometric, Voltage | 60mV/A | 1MHz | ±0.6% | ±0.5% | 4.5V ~ 5.5V | 0.5µs | 11mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
CQ3302SENSOR CURRENT HALL 20A AC/DC |
0 |
|
|
CQ | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 21A | 1 | Ratiometric, Voltage | 100mV/A | 1MHz | ±0.6% | ±0.5% | 4.5V ~ 5.5V | 0.5µs | 11mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
CQ330ASENSOR CURRENT HALL 20A AC/DC |
0 |
|
|
CQ | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 31.8A | 1 | Ratiometric, Voltage | 66mV/A | 1MHz | ±0.6% | ±0.5% | 4.5V ~ 5.5V | 0.5µs | 11mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
CQ330FSENSOR CURRENT HALL 42A AC/DC |
0 |
|
|
CQ | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 42A | 1 | Ratiometric, Voltage | 80mV/A | 1MHz | ±0.6% | ±0.5% | 4.5V ~ 5.5V | 0.5µs | 11mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
CQ330GSENSOR CURRENT HALL 4.5A AC/DC |
0 |
|
|
CQ | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 4.5A | 1 | Ratiometric, Voltage | 450mV/A | 1MHz | ±0.6% | ±0.5% | 4.5V ~ 5.5V | 0.5µs | 11mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
CQ330HSENSOR CURRENT HALL 42A AC/DC |
0 |
|
|
CQ | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 42A | 1 | Ratiometric, Voltage | 50mV/A | 1MHz | ±0.6% | ±0.5% | 4.5V ~ 5.5V | 0.5µs | 11mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
CQ3200CORELESS CURENT SENSOR / 20A W/S |
0 |
|
|
- | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 8.5A | 1 | Ratiometric, Voltage | 155mV/A | 1MHz | ±0.6% | ±1.3% | 2.7V ~ 3.63V | 500ns | 9.6mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.