Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HLSR 10-P/SP1TRANSDUCER |
0 |
|
|
HLSR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 10A | 1 | Voltage | 40mV/A | DC ~ 240kHz | ±0.5% | ±1% | 4.5V ~ 5.5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
L18P050S05RSENSOR CURRENT HALL 50A AC/DC |
0 |
|
|
L18PXXXS05 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
ACS37032LLZATR-020B3CURRENT SENSOR 5 MHZ |
0 |
|
|
- | 8-SOIC (0.154", 3.90mm Width), 6 Leads | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 20A | 1 | Analog Voltage | 66mV/A | DC ~ 5MHz | - | - | 3V ~ 3.6V | 40ns | 30mA | -40°C ~ 150°C | - | - | Bidirectional | Surface Mount | 6-SOIC |
|
ACS37030LLZATR-020B3CURRENT SENSOR 5 MHZ |
0 |
|
|
- | 8-SOIC (0.154", 3.90mm Width), 6 Leads | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 20A | 1 | Analog Voltage | 66mV/A | DC ~ 5MHz | - | - | 3V ~ 3.6V | 40ns | 30mA | -40°C ~ 150°C | - | - | Bidirectional | Surface Mount | 6-SOIC |
|
L18P005S12SENSOR CURRENT HALL 5A AC/DC |
0 |
|
|
L18PXXXS12 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 5A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 12V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
CQ3201CORELESS CURENT SENSOR / 20A W/S |
0 |
|
|
- | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 10.1A | 1 | Ratiometric, Voltage | 130mV/A | - | - | ±1.3% | 3.3V | 0.5µs | 6.2mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
L18P060S05RSENSOR CURRENT HALL 60A AC/DC |
0 |
|
|
L18PXXXS05 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 60A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L08P100D15M1SENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 10µs | 12mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L08P200D15WSENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | - | ±1% | - | 15V | 50µs | 20mA | -20°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L08P150D15M1SENSOR |
0 |
|
|
- | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 12mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L08P050D15IPVCURRENT SENSOR (50A; 15V) |
0 |
|
|
- | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 15V | 5µs | 20mA | -40°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L08P300D15IPVWCURRENT SENSOR (300A; 15V) |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | - | ±1% | - | ±12V ~ 18V | 5µs | 20mA | -40°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
L08P050D15SENSOR CURRENT HALL 50A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 10µs | 12mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
L08P150D15SENSOR CURRENT HALL 150A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 10µs | 12mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
L08P200D15SENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 10µs | 12mA | -20°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
L08P100D15SENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | ±15V | 10µs | 12mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
L18P010S05SENSOR CURRENT HALL 10A AC/DC |
0 |
|
|
L18PXXXS05 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 15mA | -30°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
HLSR 16-PW-081TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
TMCS1101A2BQDTCURRENT SENSOR |
0 |
|
|
- | 8-SOIC (0.154", 3.90mm Width) | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect | 22.5A | 1 | Ratiometric, Voltage | 100mV/A | 80kHz | ±0.05% | - | 3V ~ 5.5V | 6.5µs | 6mA | -40°C ~ 125°C | - | - | Bidirectional | Surface Mount | 8-SOIC |
|
T60404N4647X661CURRENT SENSOR, 25A, 3 PRI PINS, |
0 |
|
|
- | 10-DIP Module | Box | Active | AC/DC | Closed Loop | 25A | 1 | Ratiometric, Voltage | - | DC ~ 200kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.