Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RCT-1800-150018" COIL 1500A:333MVAC |
25 |
|
|
RCT | Module | Bag | Active | AC | Current Sensor | 1500A | 1 | Ratiometric, Voltage | - | - | - | ±1% | 12V ~ 30V | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCT-1800-500018" COIL 5000A:333MVAC |
18 |
|
|
RCT | Module | Bag | Active | AC | Current Sensor | 5000A | 1 | Ratiometric, Voltage | - | - | - | ±1% | 12V ~ 30V | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCT-1800-200018" COIL 2000A:333MVAC |
17 |
|
|
RCT | Module | Bag | Active | AC | Current Sensor | 2000A | 1 | Ratiometric, Voltage | - | - | - | ±1% | 12V ~ 30V | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCT-1800-300018" COIL 3000A:333MVAC |
10 |
|
|
RCT | Module | Bag | Active | AC | Current Sensor | 3000A | 1 | Ratiometric, Voltage | - | - | - | ±1% | 12V ~ 30V | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCT-1800-50018" COIL 500A:333MVAC |
10 |
|
|
RCT | Module | Bag | Active | AC | Current Sensor | 500A | 1 | Ratiometric, Voltage | - | - | - | ±1% | 12V ~ 30V | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCT-1800-40018" COIL 400A:333MVAC |
10 |
|
|
RCT | Module | Bag | Active | AC | Current Sensor | 400A | 1 | Ratiometric, Voltage | - | - | - | ±1% | 12V ~ 30V | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCT-1800-80018" COIL 800A:333MVAC |
7 |
|
|
RCT | Module | Bag | Active | AC | Current Sensor | 800A | 1 | Ratiometric, Voltage | - | - | - | ±1% | 12V ~ 30V | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
AT2-010-000-SPAC TRANSDUCER 200 A, 0-10 VDC |
16 |
|
|
- | Module | Box | Active | AC | Transformer w/Conditioning | 100A, 150A, 200A (Selectable) | 1 | Ratiometric, 0V ~ 10V | - | 50Hz ~ 60Hz | - | ±1% | - | 100ms | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
AT2-005-000-SPAC TRANSDUCER 200 A, 0-5 VDC |
6 |
|
|
- | Module | Box | Active | AC | Transformer w/Conditioning | 100A, 150A, 200A (Selectable) | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 60Hz | - | ±1% | - | 100ms | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
PR52-45AC CURRENT DETECTION SENSOR |
5 |
|
|
PR52 | IoT Finished Device | Box | Active | AC | Current Sensor | 100A | 1 | Wireless | - | 50Hz ~ 100kHz | ±1% | ±2% | 2V ~ 3.8V | 100ms | - | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
PR52-94-20MA CURRENT RECEIVER |
3 |
|
|
PR52 | IoT Finished Device | Box | Active | - | - | - | - | Ratiometric, 4mA ~ 20mA | - | - | - | - | 2V ~ 3.8V | - | - | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
DS3-SDT-24UCurrent Switch AC/DC, Adj. 2-100 |
4 |
|
|
- | Module, Single Pass Through | Bulk | Active | DC | Hall Effect | 20A, 50A, 100A (Selectable) | 1 | Relay, SPDT | - | DC ~ 400kHz | - | - | 15V ~ 28V | 60ms | 133mA | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
PR52-7AC CURRENT MONITOR |
5 |
|
|
PR52 | IoT Finished Device | Box | Active | AC | Current Sensor | 100A | 1 | Wireless | - | 50Hz ~ 100kHz | ±1% | ±2% | 2V ~ 3.8V | 100ms | - | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
AT2-420-24L-FTAC TRANSDUCER 200 A, 4-20 MA |
25 |
|
|
AT | Module | Box | Active | AC | Transformer w/Conditioning | 100A, 150A, 200A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 100Hz | - | ±1% | 5V ~ 40V | 300ms | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
AT0-420-24L-FTAC TRANSDUCER 5 A, 4-20 MA |
8 |
|
|
AT | Module | Box | Active | AC | Transformer w/Conditioning | 2A, 5A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 100Hz | - | ±1% | 5V ~ 40V | 300ms | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
PR55-4B2-CHANNEL AC CURRENT MONITOR |
5 |
|
|
PR55 | IoT Finished Device | Box | Active | AC | Current Sensor | 100A | 2 | Wireless | - | 50Hz ~ 100kHz | ±1% | ±2% | 2V ~ 3.8V | 100ms | - | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
AT1-420-24L-SPAC TRANSDUCER 50 A, 4-20 MA |
18 |
|
|
AT | Module | Box | Active | AC | Transformer w/Conditioning | 10A, 20A, 50A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 100Hz | - | ±1% | 5V ~ 40V | 300ms | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
AT2-420-24L-SPAC TRANSDUCER 200 A, 4-20 MA |
7 |
|
|
AT | Module | Box | Active | AC | Transformer w/Conditioning | 100A, 150A, 200A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 100Hz | - | ±1% | 5V ~ 40V | 300ms | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
PR55-4AWIRELESS AC CURRENT MONITOR |
5 |
|
|
PR55 | IoT Finished Device | Box | Active | AC | Current Sensor | 100A | 1 | Wireless | - | 50Hz ~ 100kHz | ±1% | ±2% | 2V ~ 3.8V | 100ms | - | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
DT1-420-24U-U-FLCurrent Transducer DC, 0-200 A, |
5 |
|
|
- | Module, Single Pass Through | Bulk | Active | DC | Hall Effect | 50A, 75A, 100A (Selectable) | 1 | Current | - | DC | - | ±1% | 22V ~ 26V | 60ms | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.