Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CPCO-1000-77-BP5DC-AC CURRENT PROBE, CLAMP-ON, 1 |
9 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 1000A | 1 | Ratiometric, ±5V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CPCO-1000-77-BP10DC-AC CURRENT PROBE, CLAMP-ON, 1 |
9 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 1000A | 1 | Ratiometric, ±10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CPCO-4000-77-SEDC-AC CURRENT PROBE, CLAMP-ON, 4 |
7 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 4000A | 1 | Ratiometric, 0V ~ 10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CPCO-4000-77-MADC-AC CURRENT PROBE, CLAMP-ON, 4 |
6 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 4000A | 1 | Ratiometric, 4mA ~ 20mA | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 26V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CPCO-1000-77-SEDC-AC CURRENT PROBE, CLAMP-ON, 1 |
4 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 1000A | 1 | Ratiometric, 0V ~ 10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CPCO-2000-77-SEDC-AC CURRENT PROBE, CLAMP-ON, 2 |
3 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 2000A | 1 | Ratiometric, 0V ~ 10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
MGS-1800-20003PH 18" COILS 2000A:4-20MA |
11 |
|
|
MGS | Module | Box | Active | AC | AC Single Phase/Three Phase | 2000A | 1 | Ratiometric, 4mA ~ 20mA | - | 40Hz ~ 3kHz | - | ±1% | 8V ~ 35VDC | - | - | 0°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
MGS-1800-30003PH 18" COILS 3000A:4-20MA |
10 |
|
|
MGS | Module | Box | Active | AC | AC Single Phase/Three Phase | 3000A | 1 | Ratiometric, 4mA ~ 20mA | - | 40Hz ~ 3kHz | - | ±1% | 8V ~ 35VDC | - | - | 0°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
MGS-1800-50003PH 18" COILS 5000A:4-20MA |
10 |
|
|
MGS | Module | Box | Active | AC | AC Single Phase/Three Phase | 5000A | 1 | Ratiometric, 4mA ~ 20mA | - | 40Hz ~ 3kHz | - | ±1% | 8V ~ 35VDC | - | - | 0°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
MGS-1800-40003PH 18" COILS 4000A:4-20MA |
10 |
|
|
MGS | Module | Box | Active | AC | AC Single Phase/Three Phase | 4000A | 1 | Ratiometric, 4mA ~ 20mA | - | 40Hz ~ 3kHz | - | ±1% | 8V ~ 35VDC | - | - | 0°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
MGS-1800-4003PH 18" COILS 400A:4-20MA |
10 |
|
|
MGS | Module | Box | Active | AC | AC Single Phase/Three Phase | 400A | 1 | Ratiometric, 4mA ~ 20mA | - | 40Hz ~ 3kHz | - | ±1% | 8V ~ 35VDC | - | - | 0°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
MGS-1800-2503PH 18" COILS 250A:4-20MA |
10 |
|
|
MGS | Module | Box | Active | AC | AC Single Phase/Three Phase | 250A | 1 | Ratiometric, 4mA ~ 20mA | - | 40Hz ~ 3kHz | - | ±1% | 8V ~ 35VDC | - | - | 0°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
MGS-1800-8003PH 18" COILS 800A:4-20MA |
10 |
|
|
MGS | Module | Box | Active | AC | AC Single Phase/Three Phase | 800A | 1 | Ratiometric, 4mA ~ 20mA | - | 40Hz ~ 3kHz | - | ±1% | 8V ~ 35VDC | - | - | 0°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
MGS-1800-25003PH 18" COILS 2500A:4-20MA |
10 |
|
|
MGS | Module | Box | Active | AC | AC Single Phase/Three Phase | 2500A | 1 | Ratiometric, 4mA ~ 20mA | - | 40Hz ~ 3kHz | - | ±1% | 8V ~ 35VDC | - | - | 0°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
MGS-1800-5003PH 18" COILS 500A:4-20MA |
10 |
|
|
MGS | Module | Box | Active | AC | AC Single Phase/Three Phase | 500A | 1 | Ratiometric, 4mA ~ 20mA | - | 40Hz ~ 3kHz | - | ±1% | 8V ~ 35VDC | - | - | 0°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
MGS-1800-10003PH 18" COILS 1000A:4-20MA |
10 |
|
|
MGS | Module | Box | Active | AC | AC Single Phase/Three Phase | 1000A | 1 | Ratiometric, 4mA ~ 20mA | - | 40Hz ~ 3kHz | - | ±1% | 8V ~ 35VDC | - | - | 0°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
ASR-04-3000A:333MV4" COIL 3000A:333MV 3PH INTEGRTR |
10 |
|
|
ASR-400MV | - | Bag | Active | AC | Rogowski Coil | 3000A | 3 | Ratiometric, 0V ~ 0.333V | - | 25Hz ~ 100kHz | - | ±1% | 9V ~ 36V | - | - | -20°C ~ 80°C | - | - | - | - | - |
|
ASR-04-800A:333MV4" COIL 800A:333MV 3PH INTEGRATR |
7 |
|
|
ASR-400MV | - | Bag | Active | AC | Rogowski Coil | 800A | 3 | Ratiometric, 0V ~ 0.333V | - | 25Hz ~ 100kHz | - | ±1% | 9V ~ 36V | - | - | -20°C ~ 80°C | - | - | - | - | - |
|
ASR-04-50A:333MV4" COIL 50A:333MV 3PH INTEGRATOR |
5 |
|
|
ASR-400MV | - | Bag | Active | AC | Rogowski Coil | 50A | 3 | Ratiometric, 0V ~ 0.333V | - | 25Hz ~ 100kHz | - | ±1% | 9V ~ 36V | - | - | -20°C ~ 80°C | - | - | - | - | - |
|
ASR-04-200A:333MV4" COIL 200A:333MV 3PH INTEGRATR |
5 |
|
|
ASR-400MV | - | Bag | Active | AC | Rogowski Coil | 200A | 3 | Ratiometric, 0V ~ 0.333V | - | 25Hz ~ 100kHz | - | ±1% | 9V ~ 36V | - | - | -20°C ~ 80°C | - | - | - | - | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.