Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
DCS24P100A-CL42024MM SPLIT-CORE TRUE RMS 100A 4- |
20 |
|
|
DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 100A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS24P20A-CL42024MM SPLIT-CORE TRUE RMS 20A 4-2 |
20 |
|
|
DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 20A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
|
CSNF161SENSOR CURRENT HALL 150A AC/DC |
12 |
|
|
CSN | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 150A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±12V ~ 15V | 0.5µs | 10mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
DCS35P600A-CL42035MM SPLIT-CORE TRUE RMS 600A 4- |
10 |
|
|
DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 600A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS35P500A-CL42035MM SPLIT-CORE TRUE RMS 500A 4- |
10 |
|
|
DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 500A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS35P80A-CL42035MM SPLIT-CORE TRUE RMS 80A 4-2 |
10 |
|
|
DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 80A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS35P100A-CL42035MM SPLIT-CORE TRUE RMS 100A 4- |
10 |
|
|
DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 100A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS35P200A-CL42035MM SPLIT-CORE TRUE RMS 200A 4- |
10 |
|
|
DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 200A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS35P300A-CL42035MM SPLIT-CORE TRUE RMS 300A 4- |
7 |
|
|
DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 300A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS35P400A-CL42035MM SPLIT-CORE TRUE RMS 400A 4- |
10 |
|
|
DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 400A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
JC10F-050A-V10MM CURRENT TRANS 50A:5VDC |
11 |
|
|
V | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 50A | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 60Hz | ±2% | ±2% | - | 300ms | - | -20°C ~ 50°C | - | - | - | Free Hanging | - |
|
JC10F-005A-V10MM CURRENT TRANS 5A:5VDC |
8 |
|
|
V | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 5A | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 60Hz | ±2% | ±2% | - | 300ms | - | -20°C ~ 50°C | - | - | - | Free Hanging | - |
|
332ADJUSTABLE CURRENT SENSOR |
3 |
|
|
300 | Module | Box | Active | AC/DC | Current Sensor | 20A | 3 | Relay, SPDT | - | 50Hz/60Hz | - | ±5% | 24V ~ 240V | - | - | -20°C ~ 55°C | - | - | - | DIN Rail | - |
|
CSDD1ECSENSOR CURRENT SWITCH 5A AC/DC |
0 |
|
|
CSD | 5-DIP Module | Bulk | Obsolete | AC/DC | Current Switch | 5A | 1 | NPN | - | - | - | - | 4.5V ~ 24V | 100µs | 22mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
AIMH021-050A-42021MM SPLIT-CORE 50A:4-20MA UNI |
24 |
|
|
AIMH021 | Module, Single Pass Through | Bag | Active | DC | Hall Effect | 50A | 1 | Ratiometric, 4mA ~ 20mA | - | DC | - | ±1% | ±15V | - | 35mA | -10°C ~ 85°C | - | - | Unidirectional | Panel Mount | - |
|
AIMH021-100A-42021MM SPLIT-CORE 100A:4-20MA UNI |
13 |
|
|
AIMH021 | Module, Single Pass Through | Bag | Active | DC | Hall Effect | 100A | 1 | Ratiometric, 4mA ~ 20mA | - | DC | - | ±1% | ±15V | - | 35mA | -10°C ~ 85°C | - | - | Unidirectional | Panel Mount | - |
|
AIMH021-200A-5V21MM SPLIT-CORE 200A:5V BI |
10 |
|
|
AIMH021 | Module, Single Pass Through | Bag | Active | AC/DC | Hall Effect | 200A | 1 | Ratiometric, ±5V | - | DC ~ 10kHz | - | ±1% | ±15V | - | 35mA | -10°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
AIMH021-100A-420B21MM SPLIT-CORE 100A:4-20MA BI |
6 |
|
|
AIMH021 | Module, Single Pass Through | Bag | Active | DC | Hall Effect | 100A | 1 | Ratiometric, 4mA ~ 20mA | - | DC | - | ±1% | ±15V | - | 35mA | -10°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
AIMH021-200A-42021MM SPLIT-CORE 200A:4-20MA UNI |
2 |
|
|
AIMH021 | Module, Single Pass Through | Bag | Active | DC | Hall Effect | 200A | 1 | Ratiometric, 4mA ~ 20mA | - | DC | - | ±1% | ±15V | - | 35mA | -10°C ~ 85°C | - | - | Unidirectional | Panel Mount | - |
|
|
20310300101SENSOR CURRENT HALL 300A AC |
6 |
|
|
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.5% | 15V | 1µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.