Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
TMCS1101A1BQDTCURRENT SENSOR |
55 |
|
|
- | 8-SOIC (0.154", 3.90mm Width) | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect | 45A | 1 | Ratiometric, Voltage | 50mV/A | 80kHz | ±0.05% | - | 3V ~ 5.5V | 6.5µs | 6mA | -40°C ~ 125°C | - | - | Bidirectional | Surface Mount | 8-SOIC |
|
CQ330ESENSOR CURRENT HALL 20.5A AC/DC |
89 |
|
|
CQ | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 20.5A | 1 | Ratiometric, Voltage | 200mv/A | 1MHz | ±0.6% | ±0.5% | 4.5V ~ 5.5V | 0.5µs | 11mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
T60404N4647X664CURRENT SENSOR, 50A, 3 PRI PINS, |
88 |
|
|
- | 10-DIP Module | Box | Active | AC/DC | Closed Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 200kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
TL150-A2PVCURRENT SENSOR 150A 1 CHANNEL HA |
75 |
|
|
TLxxx-A2PV | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 150A | 1 | Ratiometric, Voltage | 4.167mV/A | DC ~ 200kHz | ±0.1% | ±0.5% | 4.75V ~ 5.25V | 300ns | 14mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
TL100-A2PVCURRENT SENSOR 100A 1 CHANNEL HA |
62 |
|
|
TL1xx-A2PV | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Voltage | 6.25mV/A | DC ~ 200kHz | ±0.1% | ±0.5% | 4.75V ~ 5.25V | 300ns | 14mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
TLB6-A1PDCURRENT SENSOR 80/40A 6MA 1 CHAN |
60 |
|
|
- | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Open Loop | 80A | 1 | Voltage | - | 50Hz | - | - | 4.85V ~ 5.15V | 60ms | 6mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
TL100P-D1CCURRENT SENSOR 100A 1 CHANNEL HA |
47 |
|
|
TLx00P-D1C | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 1µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
TL300-D1CCURRENT SENSOR 300A 1 CHANNEL HA |
39 |
|
|
TLx00-D1C | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 1µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
TL200P-D1CCURRENT SENSOR 200A 1 CHANNEL HA |
32 |
|
|
TLx00P-D1C | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 1µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
TL200-D1CCURRENT SENSOR 200A 1 CHANNEL HA |
28 |
|
|
TLx00-D1C | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 1µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
TL300P-D1CCURRENT SENSOR 300A 1 CHANNEL HA |
25 |
|
|
TLx00P-D1C | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 1µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
TLB6-A1TDMCURRENT SENSOR 40A 6MA 1 CHANNEL |
20 |
|
|
- | Module | Tray | Not For New Designs | AC/DC | Open Loop | 40A | 1 | Voltage | - | 50Hz ~ 1kHz | - | - | 4.85V ~ 5.15V | 30ms | 6mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
TL100-A2TPVCURRENT SENSOR 100A 1 CHANNEL HA |
77 |
|
|
TL1xx-A2TPV | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Voltage | 6.25mV/A | DC ~ 200kHz | ±0.1% | ±0.5% | 4.75V ~ 5.25V | 300ns | 14mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
TL150-A2TPVCURRENT SENSOR 150A 1 CHANNEL HA |
65 |
|
|
TLxxx-A2TPV | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 150A | 1 | Ratiometric, Voltage | 4.167mV/A | DC ~ 200kHz | ±0.1% | ±0.5% | 4.75V ~ 5.25V | 300ns | 14mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
TL200-A2TPVCURRENT SENSOR 200A 1 CHANNEL HA |
62 |
|
|
TLxxx-A2TPV | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Voltage | 3.125mV/A | DC ~ 200kHz | ±0.1% | ±0.5% | 4.75V ~ 5.25V | 300ns | 14mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
TL100-D2CCURRENT SENSOR 100A 1 CHANNEL HA |
32 |
|
|
TLx00-D2C | Module | Box | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | ±0.05% | ±0.3% | ±12V ~ 15V | 2µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
TL300-D2CCURRENT SENSOR 300A 1 CHANNEL HA |
14 |
|
|
TLx00-D2C | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | 0.01% | ±0.3% | ±12V ~ 15V | 2µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
T60404N4647X260CURRENT SENSOR 100A/150A, PRI OP |
45 |
|
|
- | Module, Single Pass Through | Box | Active | AC/DC | Closed Loop | 100A, 150A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 1µs | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
ACI-0.5-LAC CURRENT INDICATOR, LED |
34 |
|
|
AMPFlasher™ ACI | Module | Box | Active | AC | Current Indicator | 500mA | 1 | LED | - | 50Hz ~ 400Hz | - | - | - | - | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
T60404N4646X921DIFFERENTIAL CURRENT SENSOR, 300 |
12 |
|
|
- | 10-DIP Module | Box | Active | AC/DC | Closed Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 8kHz | ±1% | ±1.5% | 4.75V ~ 5.25V | 35µs | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.