Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
791002004RESIDUAL CURRENT DETECTION SENSO |
34 |
|
|
WE-RCDS | Module | Tray | Active | DC | Current Sensor | 40A | - | - | - | 50Hz | - | - | 4.85V ~ 5.15V | - | 30mA | -40°C ~ 105°C | - | - | - | Through Hole | - |
|
|
HAS 300-PSENSOR CURRENT HALL 300A AC/DC |
81 |
|
|
HAS | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
HAS 50-PSENSOR CURRENT HALL 50A AC/DC |
72 |
|
|
HAS | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Open Loop | 50A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
RC05-300-1000TRANSF CURR SENSE 300MV/KA 50HZ |
38 |
|
|
RC05-SSSS-LLLL-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 8000A | 1 | - | 0.3mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Free Hanging | - |
|
LZSR 250-P/SP1CLOSED-LOOP CURRENT SENSOR 250A |
61 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LZSR 150-PCLOSED-LOOP CURRENT SENSOR 150A |
60 |
|
|
LZSR-P | Module | Bulk | Active | AC/DC | Closed Loop | 150A | 1 | Voltage | 4.167mV/A | DC ~ 200kHz | ±0.1% | - | 4.75V ~ 5.25V | - | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HCSP-1BS-0300AUTOMOTIVE OPEN LOOP CURRENT SEN |
20 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | 6.66mV/A | 70kHz ~ 250kHz | - | - | 4.5V ~ 5.5V | 3µs | 14mA | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
|
HCSP-1BS-0500AUTOMOTIVE OPEN LOOP CURRENT SEN |
20 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | 4mV/A | 70kHz ~ 250kHz | - | - | 4.5V ~ 5.5V | 3µs | 14mA | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
|
HCSP-1BS-1100AUTOMOTIVE OPEN LOOP CURRENT SEN |
20 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1100A | 1 | Ratiometric, Voltage | 1.81mV/A | 70kHz ~ 250kHz | - | - | 4.5V ~ 5.5V | 3µs | 14mA | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
|
HCSP-1BS-0700AUTOMOTIVE OPEN LOOP CURRENT SEN |
19 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 700A | 1 | Ratiometric, Voltage | 2.85mV/A | 70kHz ~ 250kHz | - | - | 4.5V ~ 5.5V | 3µs | 14mA | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
|
RC03-600-0250-STRANSF CURR SENSE 600MV/KA 50HZ |
38 |
|
|
RC03-SSSS-LLLL-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 2500A | 1 | - | 0.6mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Free Hanging | - |
|
HOYS 100-S/SP33-1106100A 3.3V OL BUS BAR MOUNT |
38 |
|
|
HOYS-S/SP33 | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 4.6mV/A | DC ~ 180kHz | ±0.75% | - | 3.14V ~ 3.46V | 3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HOYS 500-S-0100500A OPEN LOOP BUS BAR MOUNT |
35 |
|
|
HOYS-S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | 1.6mV/A | DC ~ 180kHz | ±0.5% | ±1% | 4.5V ~ 5.5V | 3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HOYS 500-S/SP33-1106500A 3.3V OL BUS BAR MOUNT |
20 |
|
|
HOYS-S/SP33 | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | 0.92mV/A | DC ~ 180kHz | ±0.5% | - | 3.14V ~ 3.46V | 3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HOYS 400-S/SP33-1106400A 3.3V OL BUS BAR MOUNT |
7 |
|
|
HOYS-S/SP33 | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | 1.15mV/A | DC ~ 180kHz | ±0.5% | - | 3.14V ~ 3.46V | 3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
LZSR 150-TPCLOSED-LOOP CURRENT SENSOR 150A |
10 |
|
|
LZSR-TP | Module | Bulk | Active | AC/DC | Closed Loop | 150A | 1 | Voltage | 4.167mV/A | DC ~ 200kHz | ±0.15% | - | 4.75V ~ 5.25V | - | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
RC05-150-1000TRANSF CURR SENSE 150MV/KA 50HZ |
38 |
|
|
RC05-SSSS-LLLL-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 8000A | 1 | - | 0.15mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Free Hanging | - |
|
CTSR 0.3-TP/SP4SENSOR CURRENT FLUX 300MA AC/DC |
14 |
|
|
CTSR | Module | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 300mA | 1 | Ratiometric, Voltage | - | 3.5kHz | ±0.5% | ±1.9% | 4.75V ~ 5.25V | 50µs | 21.6mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HSNBV 800-R02TRANSDUCER |
73 |
|
|
HSNBV | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 800A | 1 | Voltage | 2.5mV/A | DC ~ 1.1kHz | ±0.5% | - | 4.75V ~ 5.25V | - | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
DHAB S/157TRANSDUCER |
96 |
|
|
DHAB | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 20mV/A | DC ~ 1.1kHz | ±0.5% | ±3.75% | 4.75V ~ 5.25V | - | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.