Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ATR1-420-24L-FTAC TRANSDUCER 50 A, 0-10 VDC |
25 |
|
|
ATR | Module | Box | Active | AC | Transformer w/Conditioning | 10A, 20A, 50A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 10Hz ~ 400Hz | - | ±1% | 12V ~ 40V | 600ms | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
PR55-26C3-CHANNEL CURRENT MONITOR |
4 |
|
|
PR55 | IoT Finished Device | Box | Active | AC | Current Sensor | 100A | 3 | Wireless | - | 50Hz ~ 100kHz | ±1% | ±2% | 2V ~ 3.8V | 100ms | - | - | - | - | - | Chassis Mount | - |
|
ATR1-420-24L-SPAC TRANSDUCER 50 A, 4-20 MA |
13 |
|
|
ATR | Module | Box | Active | AC | Transformer w/Conditioning | 10A, 20A, 50A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 10Hz ~ 400Hz | - | ±1% | 12V ~ 40V | 600ms | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
ATR2-420-24L-SPAC TRANSDUCER 200 A, 4-20 MA |
7 |
|
|
ATR | Module | Box | Active | AC | Transformer w/Conditioning | 100A, 150A, 200A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 10Hz ~ 400Hz | - | ±1% | 12V ~ 40V | 600ms | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
DS50.2T50A 7MHz current sensor for SiC |
20 |
|
|
- | 8-DIP Module | Case | Active | AC/DC | Current Sensor | 50A | 1 | Voltage | 42mV/A | DC ~ 7MHz | ±1% | - | 5V | 48ns | 20mA | -40°C ~ 125°C | - | - | Bidirectional | Through Hole | - |
|
CPC-1000-27-BP2DC-AC CURRENT PROBE, CLIP-ON, 1K |
25 |
|
|
CPC | Box | Box | Active | AC/DC | Open Loop | 1000A | 1 | Ratiometric, ±2V | - | DC ~ 75kHz | ±0.2% | 1% | 3.5V ~ 5.5V | 10µs | 85mA | -40°C ~ 100°C | - | - | Bidirectional | Free Hanging | - |
|
CPC-2000-27-BP2DC-AC CURRENT PROBE, CLIP-ON, 2K |
18 |
|
|
CPC | Box | Box | Active | AC/DC | Open Loop | 2000A | 1 | Ratiometric, ±2V | - | DC ~ 75kHz | ±0.2% | 1% | 3.5V ~ 5.5V | 10µs | 85mA | -40°C ~ 100°C | - | - | Bidirectional | Free Hanging | - |
|
CPC-500-27-BP2DC-AC CURRENT PROBE, CLIP-ON, 50 |
13 |
|
|
CPC | Box | Box | Active | AC/DC | Open Loop | 500A | 1 | Ratiometric, ±2V | - | DC ~ 75kHz | ±0.2% | 1% | 3.5V ~ 5.5V | 10µs | 85mA | -40°C ~ 100°C | - | - | Bidirectional | Free Hanging | - |
|
CPC-250-27-BP2DC-AC CURRENT PROBE, CLIP-ON, 25 |
10 |
|
|
CPC | Box | Box | Active | AC/DC | Open Loop | 250A | 1 | Ratiometric, ±2V | - | DC ~ 75kHz | ±0.2% | 1% | 3.5V ~ 5.5V | 10µs | 85mA | -40°C ~ 100°C | - | - | Bidirectional | Free Hanging | - |
|
RCS-1800-10003PH 18" COILS 1000A:333MV |
15 |
|
|
RCS | Module | Bag | Active | AC | AC Single Phase/Three Phase | 1000A | 3 | Ratiometric, Voltage | - | - | - | ±1% | 9V ~ 36VDC | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCS-1800-20003PH 18" COILS 2000A:333MV |
12 |
|
|
RCS | Module | Bag | Active | AC | AC Single Phase/Three Phase | 2000A | 3 | Ratiometric, Voltage | - | - | - | ±1% | 9V ~ 36VDC | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCS-1800-30003PH 18" COILS 3000A:333MV |
10 |
|
|
RCS | Module | Bag | Active | AC | AC Single Phase/Three Phase | 3000A | 3 | Ratiometric, Voltage | - | - | - | ±1% | 9V ~ 36VDC | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCS-1800-40003PH 18" COILS 4000A:333MV |
10 |
|
|
RCS | Module | Bag | Active | AC | AC Single Phase/Three Phase | 4000A | 3 | Ratiometric, Voltage | - | - | - | ±1% | 9V ~ 36VDC | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCS-1800-4003PH 18" COILS 400A:333MV |
6 |
|
|
RCS | Module | Bag | Active | AC | AC Single Phase/Three Phase | 400A | 3 | Ratiometric, Voltage | - | - | - | ±1% | 9V ~ 36VDC | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCS-1800-50003PH 18" COILS 5000A:333MV |
4 |
|
|
RCS | Module | Bag | Active | AC | AC Single Phase/Three Phase | 5000A | 3 | Ratiometric, Voltage | - | - | - | ±1% | 9V ~ 36VDC | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
S9XM300A1000VMPOWER METER / CT RS485 MODBUS |
9 |
|
|
- | Module, Single Pass Through | Bag | Active | AC/DC | Current Sensor | 300A | 1 | - | - | DC, 1Hz ~ 400Hz | - | ±0.5% | 9V ~ 30V | - | - | -15°C ~ 65°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CPCO-2000-77-BP10DC-AC CURRENT PROBE, CLAMP-ON, 2 |
19 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 2000A | 1 | Ratiometric, ±10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CPCO-4000-77-BP5DC-AC CURRENT PROBE, CLAMP-ON, 4 |
17 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 4000A | 1 | Ratiometric, ±5V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CPCO-2000-77-MADC-AC CURRENT PROBE, CLAMP-ON, 2 |
10 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 2000A | 1 | Ratiometric, 4mA ~ 20mA | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 26V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CPCO-1000-77-MADC-AC CURRENT PROBE, CLAMP-ON, 1 |
9 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 1000A | 1 | Ratiometric, 4mA ~ 20mA | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 26V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.
