Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ASR-04-500A:333MV4" COIL 500A:333MV 3PH INTEGRATR |
3 |
|
|
ASR-400MV | - | Bag | Active | AC | Rogowski Coil | 500A | 3 | Ratiometric, 0V ~ 0.333V | - | 25Hz ~ 100kHz | - | ±1% | 9V ~ 36V | - | - | -20°C ~ 80°C | - | - | - | - | - |
|
ASR-04-1200A:4-20MA4" COIL 1200A:4-20MA 3PH INTGRTR |
10 |
|
|
ASR-400MV | - | Bag | Active | AC | Rogowski Coil | 1200A | 3 | Ratiometric, 4mA ~ 20mA | - | 40Hz ~ 3kHz | - | ±1% | 8V ~ 35V | - | - | -20°C ~ 80°C | - | - | - | - | - |
|
ASR-07-800A:4-20MA7" COIL 800A:4-20MA 3PH INTEGRTR |
10 |
|
|
ASR-400MV | - | Bag | Active | AC | Rogowski Coil | 800A | 3 | Ratiometric, 4mA ~ 20mA | - | 40Hz ~ 3kHz | - | ±1% | 8V ~ 35V | - | - | -20°C ~ 80°C | - | - | - | - | - |
|
ASR-07-100A:4-20MA7" COIL 100A:4-20MA 3PH INTEGRTR |
5 |
|
|
ASR-400MV | - | Bag | Active | AC | Rogowski Coil | 100A | 3 | Ratiometric, 4mA ~ 20mA | - | 40Hz ~ 3kHz | - | ±1% | 8V ~ 35V | - | - | -20°C ~ 80°C | - | - | - | - | - |
|
CPCO-12000-77-MADC-AC CURRENT PROBE, CLAMP-ON, 1 |
10 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 12000A | 1 | Ratiometric, 4mA ~ 20mA | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 26V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CPCO-12000-77-BP10DC-AC CURRENT PROBE, CLAMP-ON, 1 |
9 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 12000A | 1 | Ratiometric, ±10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CPCO-12000-77-BP5DC-AC CURRENT PROBE, CLAMP-ON, 1 |
5 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 12000A | 1 | Ratiometric, ±5V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CPCO-8000-77-BP10DC-AC CURRENT PROBE, CLAMP-ON, 8 |
4 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 8000A | 1 | Ratiometric, ±10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 47mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
RCS-1805-VAR3PH 18" COILS SELECTABLE IN:5A |
10 |
|
|
RCS-XX05-VAR | Module | Bag | Active | AC | AC Single Phase/Three Phase | Programmable | 3 | Ratiometric, Current | - | 50Hz ~ 60Hz | - | ±1% | 24VDC | - | - | -20°C ~ 55°C | - | - | - | DIN Rail | - |
|
RCS-2405-VAR3PH 24" COILS SELECTABLE IN:5A |
10 |
|
|
RCS-XX05-VAR | Module | Bag | Active | AC | AC Single Phase/Three Phase | Programmable | 1 | Ratiometric, Current | - | 50Hz ~ 60Hz | - | ±1% | 24VDC | - | - | -20°C ~ 55°C | - | - | - | DIN Rail | - |
|
RIK-5A:RCT163PH 5A INT 4" COIL KIT |
5 |
|
|
RIK | - | Tape & Box (TB) | Active | AC | Rogowski Coil | 500A, 1000A, 2500A, 5000A, 10000A, 25000A, 50000A (Selectable) | 3 | Ratiometric, 5A | - | 50/60Hz | - | ±1% | 24VDC | 10ms | - | -20°C ~ 55°C | - | - | - | DIN Rail, Panel | - |
|
CPCO-4000-160-BP10DC-AC CURRENT PROBE, CLAMP-ON, 4 |
10 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 4000A | 1 | Ratiometric, ±10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 80mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CPCO-1000-160-BP10DC-AC CURRENT PROBE, CLAMP-ON, 1 |
10 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 1000A | 1 | Ratiometric, ±10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 80mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CPCO-2000-160-SEDC-AC CURRENT PROBE, CLAMP-ON, 2 |
10 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 2000A | 1 | Ratiometric, 0V ~ 10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 80mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CPCO-16000-160-MADC-AC CURRENT PROBE, CLAMP-ON, 1 |
10 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 16000A | 1 | Ratiometric, 4mA ~ 20mA | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 26V | 10µs | 80mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
CPCO-16000-160-BP10DC-AC CURRENT PROBE, CLAMP-ON, 1 |
10 |
|
|
CPCO | Box | Box | Active | AC/DC | Open Loop | 16000A | 1 | Ratiometric, ±10V | - | DC ~ 40kHz | ±0.5% | 1% | 11V ~ 31V | 10µs | 80mA | -40°C ~ 100°C | - | - | Bidirectional | Panel Mount | - |
|
DM1200UB-10VCURRENT TRANSDUCER 1200A |
3 |
|
|
DM | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 1200A | 1 | Ratiometric, Voltage | - | DC ~ 300kHz | ±0.0015% | - | ±14.25V ~ 15.75V | 1µs | 141mA | -40°C ~ 65°C | - | - | Bidirectional | Chassis Mount | - |
|
TMR7302-250E/PFF5BBMini TMR Current Sensor NOM 250A |
50 |
|
|
- | 5-CB Formed Leads, PFF | Bulk | Active | AC/DC | Open Loop | 250A | 1 | Analog Voltage | 8mV/A | 50kHz | ±0.5% | ±2% | 4.75V ~ 5.25V | 10µs | 7.5mA | -40°C ~ 125°C | - | - | Bidirectional | Through Hole | - |
|
TMR7302-100E/PFF5BBMini TMR Current Sensor NOM 100A |
50 |
|
|
- | 5-CB Formed Leads, PFF | Bulk | Active | AC/DC | Open Loop | 100A | 1 | Analog Voltage | 20mV/A | 50kHz | ±0.5% | ±2% | 4.75V ~ 5.25V | 10µs | 7.5mA | -40°C ~ 125°C | - | - | Bidirectional | Through Hole | - |
|
TMR7302-200E/PFF5BBMini TMR Current Sensor NOM 200A |
50 |
|
|
- | 5-CB Formed Leads, PFF | Bulk | Active | AC/DC | Open Loop | 200A | 1 | Analog Voltage | 10mV/A | 50kHz | ±0.5% | ±2% | 4.75V ~ 5.25V | 10µs | 7.5mA | -40°C ~ 125°C | - | - | Bidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.