Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
DS400IDCURRENT TRANSDUCER 400A |
8 |
|
|
DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 400A | 1 | - | - | DC ~ 300kHz | ±0.00015% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS300IDCURRENT TRANSDUCER 300A |
3 |
|
|
DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 300A | 1 | - | - | DC ~ 1MHz | ±0.00015% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS600IDCURRENT TRANSDUCER 600A |
11 |
|
|
DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 600A | 1 | - | - | DC ~ 500kHz | ±0.0001% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS200UB-10VCURRENT TRANSDUCER 200A |
10 |
|
|
DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 500kHz | ±0.005% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS400UB-10VCURRENT TRANSDUCER 400A |
4 |
|
|
DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 400A | 1 | - | - | DC ~ 500kHz | ±0.0015% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS600UB-10VCURRENT TRANSDUCER 600A |
5 |
|
|
DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 300kHz | ±0.004% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DN1000ID1000A CURRENT TRANSDUCER CURRENT |
12 |
|
|
DN | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 1000A | 1 | Ratiometric, Current | - | 31.25kHz | - | - | 14.25V ~ 15.75V | 1µs | 1.1A | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS1000UB-10VCURRENT TRANSDUCER 1000A |
2 |
|
|
DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 1000A | 1 | Ratiometric, Voltage | - | DC ~ 300kHz | ±0.0035% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 55°C | - | - | Bidirectional | Chassis Mount | - |
|
IN 1000-S1000A ULTRA ACCURACY |
2 |
|
|
IN | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Closed Loop | 1000A | 1 | Current | - | DC ~ 440kHz | ±0.0002% | - | ±14.25V ~ 15.75V | 1µs | 1.12A (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DM1200IDCURRENT TRANSDUCER 1200A |
10 |
|
|
DM | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 1200A | 1 | Ratiometric, Current | - | DC ~ 300kHz | ±0.0001% | - | ±14.25V ~ 15.75V | 1µs | 120mA | -40°C ~ 65°C | - | - | Bidirectional | Chassis Mount | - |
|
IN 2000-S2000A ULTRA ACCURACY |
2 |
|
|
IN | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Closed Loop | 2000A | 1 | Current | - | DC ~ 140kHz | ±0.0002% | - | ±14.25V ~ 15.75V | 1µs | 1.725A | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
MCS1802GS-40-P3.3V, LINEAR HALL-EFFECT CURRENT |
50 |
|
|
- | 8-SOIC (0.154", 3.90mm Width) | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 40A | 1 | Ratiometric, Voltage | 33mV/A | 100kHz | ±0.5% | ±2.5% | 3V ~ 3.6V | 5µs | 10.5mA | -40°C ~ 125°C (TJ) | - | - | Bidirectional | Surface Mount | 8-SOIC |
|
HO 150-NP-0100SENSOR CURRENT HALL 150A AC/DC |
60 |
|
|
HO-NP | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | - | DC ~ 350kHz | ±0.4% | ±1.2% | 5V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 75-P/SP11 MHZ OPEN-LOOP CURRENT SENSOR 7 |
98 |
|
|
HOB-P/SP1 | Module | Bulk | Active | AC/DC | Open Loop | 75A | 1 | Voltage | 21.333mV/A | 1MHz | ±0.6% | - | 4.6V ~ 5.5V | - | 26mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 130-P/SP331 MHZ OPEN-LOOP CURRENT SENSOR 1 |
71 |
|
|
HOB-P/SP33 | Module | Bulk | Active | AC/DC | Open Loop | 130A | 1 | Voltage | 4.6mV/A | 1MHz | ±0.45% | - | 3.14V ~ 3.46V | - | 24mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 50-P1 MHZ OPEN-LOOP CURRENT SENSOR 5 |
62 |
|
|
HOB-P | Module | Bulk | Active | AC/DC | Open Loop | 50A | 1 | Voltage | 16mV/A | 1MHz | ±0.7% | - | 4.6V ~ 5.5V | 200ns | 26mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 50-P/SP331 MHZ OPEN-LOOP CURRENT SENSOR 5 |
36 |
|
|
HOB-P/SP33 | Module | Bulk | Active | AC/DC | Open Loop | 50A | 1 | Voltage | 9.2mV/A | 1MHz | ±0.7% | - | 3.14V ~ 3.46V | - | 24mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 120-PSENSOR CURRENT HALL 120A AC/DC |
75 |
|
|
HO-P | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 120A | 1 | Ratiometric, Voltage (Selectable) | - | DC ~ 100kHz | ±0.5% | ±1% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 100-PSENSOR CURRENT HALL 100A AC/DC |
66 |
|
|
HO-P | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage (Selectable) | - | DC ~ 100kHz | ±0.5% | ±1% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
CSHV200A-001CSHV200A-001 CURRENT SENSOR |
20 |
|
|
CSHV | Module, Single Pass Through | Box | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 10mV/A | 45kHz | ±1% | ±2% | 4.5V ~ 5.5V | 6µs | 16mA | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.