Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CR4220-5SENSOR CURRENT XFMR 5A AC |
7 |
|
|
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
|
CR4220-10SENSOR CURRENT XFMR 10A AC |
5 |
|
|
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 10A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
|
CR5410-50SENSOR CURRENT HALL 50A AC/DC |
7 |
|
|
CR5400 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 4kHz | - | ±1% | 24V | - | 40mA | 0°C ~ 50°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR5410-300SENSOR CURRENT HALL 300A AC/DC |
5 |
|
|
CR5400 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 4kHz | - | ±1% | 24V | - | 40mA | 0°C ~ 50°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
HTR 300-SBSENSOR CURRENT HALL 300A AC/DC |
20 |
|
|
HTR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 10kHz | ±1% | ±2% | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
SSD-500A-C100A - 24BIT ISOLATED SHUNT CUR |
22 |
|
|
SSD | Module | Bulk | Active | DC | Current Sensor | 500A | 1 | CAN Bus | - | - | ±0.1% | ±0.1% | 24V ~ 60V | - | 15mA (Typ) | -40°C ~ 115°C | - | - | Bidirectional | Chassis Mount | - |
|
|
CSNS300FSENSOR CURRENT HALL 600A AC/DC |
13 |
|
|
CSN | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.1% | ±5% | 15V | 500ns | 160mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CR4110-10SENSOR CURRENT XFMR 10A AC |
3 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 10A | 1 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4110-25SENSOR CURRENT XFMR 25A AC |
2 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 25A | 1 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
2910322PACT RCP-D95-5M |
5 |
|
|
- | - | Bulk | Active | AC | Current Sensor | - | 1 | Voltage | - | 40Hz ~ 20kHz | ±0.1% | ±0.02% | - | - | - | -30°C ~ 80°C | - | - | - | Busbar (Clamp-on) | - |
|
CR4120-100SENSOR CURRENT XFMR 100A AC |
4 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 100A | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 40mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
DHR 200 C5SENSOR CURRENT HALL 200A AC/DC |
15 |
|
|
DHR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, 0V ~ 5V | - | DC ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Bidirectional | Panel Mount | - |
|
DHR 200 C10SENSOR CURRENT HALL 200A AC/DC |
12 |
|
|
DHR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, 0V ~ 10V | - | DC ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Bidirectional | Panel Mount | - |
|
ES-600SHUNT DATA RECORDER |
10 |
|
|
- | Module | Box | Active | DC | Current Sensor | 600A | 1 | CAN Bus | - | - | 0.01% | ±0.1% | 4.5V ~ 40V | 200ms | 18mA | -40°C ~ 105°C | Automotive | AEC-Q101 | Unidirectional | Chassis Mount | - |
|
CR5410S-50SENSOR CURRENT HALL 50A AC/DC |
4 |
|
|
CR5410S | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 4kHz | - | ±1% | 24V | - | 35mA | 0°C ~ 50°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4480-5SENSOR CURRENT XFMR 5A AC |
4 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 3 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 120mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
KIT-ICD-A-100-CAN1-12CURRENT SENSOR WITH CONNECTOR |
19 |
|
|
ICD | Module | Tray | Active | DC | Shunt | 100A | 1 | CAN Bus | - | - | ±0.1% | ±0.8% | 5.5V ~ 26V | - | 50mA | -40°C ~ 105°C | Automotive | - | Bidirectional | Chassis Mount | - |
|
1510470000CONDITIONER SIGNAL RAIL MNT |
2 |
|
|
- | Module | Bulk | Active | AC/DC | - | 10A | 1 | Ratiometric, Voltage and Current | - | - | - | - | 18V ~ 30V | - | - | -25°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
|
DHR 1000 C10SENSOR CURRENT HALL 1000A AC/DC |
5 |
|
|
DHR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Ratiometric, 0V ~ 10V | - | DC ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Bidirectional | Panel Mount | - |
|
KIT - IVT-S-300-U3-I-CAN1-12/24 W/ CONNECTORKIT - IVT-S-300-U3-I-CAN1-12/24 |
17 |
|
|
- | - | Tray | Active | - | Shunt | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.