Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AT 20 B10SENSOR CURRENT XFMR 20A AC |
2 |
|
|
AT | Module | Bulk | Active | AC | Transformer w/Conditioning | 20A | 1 | Ratiometric, 0V ~ 10V | - | 50/60Hz | ±0.5% | ±1.5% | Self Powered | 300ms | - | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 210-SCUR TRANSDUCER CLO LOOP 200A |
4 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Current | 0.5mA/A | 100kHz | ±0.05% | ±0.2% | 11.4V ~ 15.75V | 0.5µs | 35mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
AT 50 B5SENSOR CURRENT XFMR 50A AC |
2 |
|
|
AT | Module | Bulk | Active | AC | Transformer w/Conditioning | 50A | 1 | Ratiometric, 0V ~ 5V | - | 50/60Hz | ±0.5% | ±1.5% | Self Powered | 300ms | - | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
HAC 600-SSENSOR CURRENT HALL 600A AC/DC |
12 |
|
|
HAC | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 7µs | 25mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
HAC 800-SSENSOR CURRENT HALL 800A AC/DC |
9 |
|
|
HAC | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 800A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 7µs | 25mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 306-SSENSOR CURRENT HALL 300A AC/DC |
2 |
|
|
LF | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.4% | ±12V ~ 15V | 1µs | 170mA | -25°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CR4220-20SENSOR CURRENT XFMR 20A AC |
20 |
|
|
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 20A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
|
AT 150 B420LSENSOR CURRENT XFMR 150A AC |
23 |
|
|
AT | Module | Bulk | Active | AC | Transformer w/Conditioning | 150A | 1 | Ratiometric, 4mA ~ 20mA | - | 50/60Hz | ±0.5% | ±1.5% | 20V ~ 30V | 100ms | 30mA | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
HAX 2500-SSENSOR CURRENT HALL 2500A AC/DC |
11 |
|
|
HAX | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 2500A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HAX 2000-SSENSOR CURRENT HALL 2000A AC/DC |
7 |
|
|
HAX | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 2000A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CR5410-20SENSOR CURRENT HALL 20A AC/DC |
17 |
|
|
CR5400 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 20A | 1 | Ratiometric, Voltage | - | DC ~ 4kHz | - | ±1% | 24V | - | 40mA | 0°C ~ 50°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR5210-10SENSOR CURRENT MAGNETIC 10A DC |
15 |
|
|
CR5200 | Module | Bulk | Active | DC | Magnetic Modulator, Closed Loop | 10A | 1 | Ratiometric, Voltage | - | DC | - | ±1% | 24V | 250ms | 40mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
CR5210-2SENSOR CURRENT MAGNETIC 2A DC |
15 |
|
|
CR5200 | Module | Bulk | Active | DC | Magnetic Modulator, Closed Loop | 2A | 1 | Ratiometric, Voltage | - | DC | - | ±1% | 24V | 250ms | 40mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
CR5210-5SENSOR CURRENT MAGNETIC 5A DC |
13 |
|
|
CR5200 | Module | Bulk | Active | DC | Magnetic Modulator, Closed Loop | 5A | 1 | Ratiometric, Voltage | - | DC | - | ±1% | 24V | 250ms | 40mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
CR5410-30SENSOR CURRENT HALL 30A AC/DC |
7 |
|
|
CR5400 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 30A | 1 | Ratiometric, Voltage | - | DC ~ 4kHz | - | ±1% | 24V | - | 40mA | 0°C ~ 50°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR5211-20SENSOR CURRENT HALL 20A DC |
2 |
|
|
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 20A | 1 | Ratiometric, ±10V | - | DC | - | ±1% | 24V | 250ms | 40mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
CR5220-2SENSOR CURRENT MAGNETIC 2A DC |
21 |
|
|
CR5200 | Module | Bulk | Active | DC | Magnetic Modulator, Closed Loop | 2A | 1 | Ratiometric, 4mA ~ 20mA | - | DC | - | ±1% | 24V | 250ms | 100mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
CR5220-5SENSOR CURRENT MAGNETIC 5A DC |
12 |
|
|
CR5200 | Module | Bulk | Active | DC | Magnetic Modulator, Closed Loop | 5A | 1 | Ratiometric, 4mA ~ 20mA | - | DC | - | ±1% | 24V | 250ms | 100mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
CR5220-20SENSOR CURRENT HALL 20A DC |
7 |
|
|
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 20A | 1 | Ratiometric, 4mA ~ 20mA | - | DC | - | ±1% | 24V | 250ms | 100mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
|
CR5220-150SENSOR CURRENT HALL 150A DC |
6 |
|
|
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 150A | 1 | Ratiometric, 4mA ~ 20mA | - | DC | - | ±1% | 24V | 250ms | 100mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.