Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RCS-1800-8003PH 18" COILS 800A:333MV |
93 |
|
|
RCS | Module | Bag | Active | AC | AC Single Phase/Three Phase | 800A | 3 | Ratiometric, Voltage | - | - | - | ±1% | 9V ~ 36VDC | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCS-1800-2503PH 18" COILS 250A:333MV |
31 |
|
|
RCS | Module | Bag | Active | AC | AC Single Phase/Three Phase | 250A | 3 | Ratiometric, Voltage | - | - | - | ±1% | 9V ~ 36VDC | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCS-1800-15003PH 18" COILS 1500A:333MV |
30 |
|
|
RCS | Module | Bag | Active | AC | AC Single Phase/Three Phase | 1500A | 3 | Ratiometric, Voltage | - | - | - | ±1% | 9V ~ 36VDC | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
T60404N4646X653CURRENT SENSOR, 6A, 3 PRI |
497 |
|
|
- | 9-DIP Module | Bulk | Active | AC/DC | Closed Loop | 6A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
HS100T01100 Amps rated open loop Hall ef |
1,600 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 100A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
HS300T01300 Amps rated open loop Hall ef |
352 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 300A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
HS200T01200 Amps rated open loop Hall ef |
345 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 200A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
HS050T0150 Amps rated open loop Hall eff |
340 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 50A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
HS400T01400 Amps rated open loop Hall ef |
155 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 400A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
T60404N4646X662Closed Loop Current Sensor DC |
240 |
|
|
- | 10-DIP Module | Bulk | Active | AC/DC | Closed Loop | 15A | 1 | Ratiometric, Voltage | - | DC ~ 200kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
T60404N4646X664Closed Loop Current Sensor AC/ |
215 |
|
|
- | 10-DIP Module | Bulk | Active | AC/DC | Closed Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 200kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 300ns | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
VH1K0T02Voltage sensors 1000 Vrms rating |
700 |
|
|
- | 5-DIP Module | Bulk | Active | AC/DC | Hall Effect | 10mA | 1 | Current | - | - | ±0.2% | ±0.8% | ±15V | - | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HK500T09500 Amps rated Split core Hall e |
200 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 500A | 1 | Analog Voltage | - | DC ~ 20kHz | ±1% | ±2% | ±15V | 3µs | 25mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HK100T09100 Amps rated Split core Hall e |
110 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 100A | 1 | Analog Voltage | - | DC ~ 20kHz | ±1% | ±2% | ±15V | 3µs | 25mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HSS500T01500 Amps rated open loop Hall ef |
157 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 500A | 1 | Analog Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 15mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HJ200T02200 Amps rated Split core Hall e |
120 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 200A | 1 | Analog Voltage | - | DC ~ 20kHz | ±1% | ±2% | 5V | - | 18mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HSS800T01800 Amps rated open loop Hall ef |
107 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 800A | 1 | Analog Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 15mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HJ050T0250 Amps rated Split core Hall ef |
102 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 50A | 1 | Analog Voltage | - | DC ~ 20kHz | ±1% | ±2% | 5V | - | 18mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HE300T04300 Amps rated closed loop Hall |
1,800 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 300A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.1% | ±0.8% | ±12V ~ 15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HE200T04200 Amps rated closed loop Hall |
435 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 200A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.1% | ±0.8% | ±12V ~ 15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.