Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
VJ1K5T03Voltage sensors 1500 Vrms rating |
100 |
|
|
- | Module | Bulk | Active | AC/DC | Current Sensor | - | 1 | Current | - | DC ~ 14kHz | ±1% | ±1% | 13.5V ~ 26.4V | 60µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LXS 25-NPSSENSOR CURRENT HALL 25A UNIPOLAR |
75 |
|
|
LXS | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | 300kHz | ±0.1% | ±2.25% | 4.75V ~ 5.25V | 400ns | 32.5mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LES 6-NPSENSOR CURRENT HALL 6A UNIPOLAR |
9 |
|
|
LES | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±0.1% | ±2.25% | 4.75V ~ 5.25V | 400ns | 23mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LKSR 50-NPSENSOR CURRENT HALL 50A UNIPOLAR |
76 |
|
|
LKSR | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 51.3mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HC5FW 500-S/SP1AUTOMOTIVE GRADE CURRENT SENSOR |
37 |
|
|
HC5FW | Module, Single Pass Through | Box | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | 4mV/A | DC ~ 40kHz | ±1% | ±2% | 4.75V ~ 5.25V | 6µs | 25mA | -40°C ~ 125°C | - | - | Unidirectional | Through Hole | - |
|
|
HAS 100-SSENSOR CURRENT HALL 100A AC/DC |
98 |
|
|
HAS | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
LA 150-PSENSOR CURRENT HALL 150A AC/DC |
36 |
|
|
LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 150A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±1% | ±0.5% | ±12V ~ 15V | 0.5µs | 10mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
|
HAS 300-SSENSOR CURRENT HALL 300A AC/DC |
98 |
|
|
HAS | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
HAS 400-SSENSOR CURRENT HALL 400A AC/DC |
82 |
|
|
HAS | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
LAH 125-PSENSOR CURRENT HALL 125A AC/DC |
18 |
|
|
LAH | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 125A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.15% | ±0.41% | ±12V ~ 15V | 1µs | 144mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LDSR 0.3-NP3 PHASE LEAKAGE CURRENT DETECTIO |
60 |
|
|
LDSR-NP | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300mA | 1 | Ratiometric, Voltage | 2.2V/A | DC ~ 2kHz | ±3% | - | 4.75V ~ 5.25V | 300µs | 20.5mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LZSR 200-P/SP1CLOSED-LOOP CURRENT SENSOR 200A |
39 |
|
|
LZSR-P/SP1 | Module | Bulk | Active | AC/DC | Closed Loop | 200A | 1 | Voltage | 3.125mV/A | DC ~ 200kHz | ±0.15% | - | 4.75V ~ 5.25V | - | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LA 100-TPSENSOR CURRENT HALL 100A AC/DC |
90 |
|
|
LA | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.15% | ±0.45% | ±12V ~ 15V | 1µs | 10mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CR9580-20SENSOR CURRENT XFMR 20A AC |
68 |
|
|
CR9500 | Hinged Ring, 0.40" Dia, Wire Leads | Bulk | Active | AC | Transformer w/Conditioning | 20A | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | - | - | Bidirectional | - | - |
|
CR9580-10SENSOR CURRENT XFMR 10A AC |
60 |
|
|
CR9500 | Hinged Ring, 0.40" Dia, Wire Leads | Bulk | Active | AC | Transformer w/Conditioning | 10A | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | - | - | Bidirectional | - | - |
|
CR9521-20SENSOR CURRENT XFMR 20A AC |
39 |
|
|
CR9500 | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 20A | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | - | - | Bidirectional | - | - |
|
|
CR9380-NPNSENSOR CURRENT SWITCH 100A NPN |
37 |
|
|
CR9380 | Module, Single Pass Through | Bulk | Active | AC | Current Switch | 100A | 1 | NPN | - | 50Hz ~ 400Hz | - | - | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | - | - | Bidirectional | - | - |
|
|
CTSR 0.6-PSENSOR CURRENT FLUX 600MA AC/DC |
39 |
|
|
CTSR | Module | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 600mA | 1 | Ratiometric, Voltage | - | 9.5kHz | ±0.4% | ±1.5% | 4.75V ~ 5.25V | 30µs | 21.6mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LA 25-PSENSOR CURRENT HALL 25A AC/DC |
98 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.15% | ±0.91% | ±12V ~ 15V | 1µs | 10mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
DHAB S/124SENSOR CURRENT 75A/500A 2CH |
75 |
|
|
DHAB | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 75A, 500A | 2 | Voltage | 26.7mV/A | DC ~ 70Hz | ±0.5% | - | 4.75V ~ 5.25V | - | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.