Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
DK 300 B420TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DK 200 B420TRANSDUCER |
0 |
|
|
DK | Module, Single Pass Through | Bulk | Active | DC | Hall Effect, Open Loop | 100A, 150A, 200A (Selectable) | 1 | Current | - | DC | ±0.75% | ±2% | 20V ~ 45V | 100ms | 100mA | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
DK 400 B420TRANSDUCER |
0 |
|
|
DK | Module | Bulk | Active | DC | Current Transducer | 200A, 300A, 400A (Selectable) | 1 | Current | - | DC | ±0.75% | ±2% | 20V ~ 45V | 100ms | 100mA | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
DK 200 B420 UTRANSDUCER |
0 |
|
|
DK | Module, Single Pass Through | Bulk | Active | DC | Hall Effect, Open Loop | 100A, 150A, 200A (Selectable) | 1 | Current | - | DC | ±0.75% | ±2% | 20V ~ 45V | 100ms | 100mA | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
HAT 163-T/SP17TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 1005-S/SP34TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CSNJ481SENSOR CURRENT HALL 600A AC/DC |
0 |
|
|
CSN | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 600A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±12V ~ 18V | 0.5µs | 14mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HAZ 4000-SBITRANSDUCER |
0 |
|
|
HAZ | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 4000A | 1 | Current | - | DC ~ 3kHz | ±0.5% | ±1% | ±15V | 10µs | 50mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
AKR 5 B420LTRANSDUCER |
0 |
|
|
AKR | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 2A, 5A (Selectable) | 1 | Current | - | 10Hz ~ 400Hz | - | ±1% | 24V | 600ms | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
DK 100 B420TRANSDUCER |
0 |
|
|
DK | Module, Single Pass Through | Bulk | Active | DC | Current Transducer | 50A, 75A, 100A (Selectable) | 1 | Current | - | DC | ±0.75% | ±2% | 20V ~ 45V | 100ms | 100mA | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
LA 205-S/SP32SENSORS |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR4111-0.5SENSOR CURRENT XFMR 0.5A AC |
0 |
|
|
CR4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 500mA | 1 | Ratiometric, 0V ~ 10V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 25mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
789-620CURRENT SENSOR WITH BUS CONNECTI |
0 |
|
|
- | Module | Box | Active | DC | Current Sensor | 80A | 1 | - | - | - | - | - | - | - | - | -20°C ~ 70°C | - | - | - | DIN Rail | - |
|
CRD5110-XX-XX-MCRD5110-XX-XX-M |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 2005-S/SP33TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 2005-S/SP6TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2005-S/SP46TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
VTUF-420-24U-DINAC/DC TRANSDUCER 150 VOLTS INPUT |
0 |
|
|
VTU-DIN | Module | Box | Active | AC/DC | Current Sensor | - | 1 | Ratiometric, 4mA ~ 20mA | - | 0Hz ~ 5kHz | - | ±1% | 24V | 500ms | - | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2010-S/SP36TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LT 200-S/SP42TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.