Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CTL2002FSENSOR CURRENT 100A, 150A, 200A |
0 |
|
|
CTL | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 100A, 150A, 200A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 100Hz | - | ±0.5% | 24V | 300ms | 40mA | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 1000-SC/SP6TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LTC 1000-TF/SP14TRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 600-T/SP16TRANSDUCER |
0 |
|
|
LTC | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 600A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.7% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 600-T/SP10TRANSDUCER |
0 |
|
|
LTC | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
ISOBLOCK I-ST-1C (30A 10V)TRANSDUCER CURRENT 9-28VDC |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 30A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 2.8µs | - | -25°C ~ 70°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (2A 10V)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 2A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (5A 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 5A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (20A 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 20A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (500MA 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 500mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (200MA 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 200mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (40A 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 40A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (5MA 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 5mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (30MA 10V)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 30mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (4A 10V)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 4A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (3MA 10V)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 3mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (6MA 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 6mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (6MA 10V)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 6mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (10MA 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 10mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
ISOBLOCK I-ST-1C (3A 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
|
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 3A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.