Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HOP 1000-SBCURRENT SENS OPEN LOOP 1000A |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LTC 1000-SF/SP4TRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 1000-SF/SP14TRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 1000-SF/SP24TRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 1000-SF/SP33TRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 1000-SF/SP19TRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
20311009101SENSOR CURRENT HALL 1000A AC |
0 |
|
|
HCMR | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.4% | 15V ~ 24V | 1µs | 28mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
DK 20 C420 BTRANSDUCER |
0 |
|
|
DK | Module, Single Pass Through | Bulk | Active | DC | Current Transducer | 5A, 10A, 20A (Selectable) | 1 | Current | - | DC | ±0.75% | ±1% | 20V ~ 45V | 20ms | 100mA | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
DK 100 B10TRANSDUCER |
0 |
|
|
DK | Module, Single Pass Through | Bulk | Active | DC | Hall Effect, Open Loop | 50A, 75A, 100A (Selectable) | 1 | Voltage | - | DC | ±0.75% | ±2% | 20V ~ 45V | 100ms | 100mA | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
DK 100 B5TRANSDUCER |
0 |
|
|
DK | Module, Single Pass Through | Bulk | Active | DC | Hall Effect, Open Loop | 50A, 75A, 100A (Selectable) | 1 | Voltage | - | DC | ±0.75% | ±2% | 20V ~ 45V | 100ms | 100mA | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
HOP 2000-SBTRANSDUCER |
0 |
|
|
HOP | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 2000A | 1 | Analog Voltage | - | DC ~ 10kHz | ±0.1% | ±2% | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 1000-TTRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
IVT-S-2K5-U3-I-CAN1-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
0 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 2500A | 3 | CAN Bus | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
LV 100/SP41SENSORS |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LTC 1000-SF/SP23TRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
AKR 50 C420LCURRENT TRANS 10,20,50A DIN |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
ART-D125/SP3 W. AI-PMULTRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CSNK591SENSOR CURRENT HALL 1200A AC/DC |
0 |
|
|
CSN | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1200A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±15V ~ 24V | 1µs | 22mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
VTUJ-420-24U-DINAC/DC TRANSDUCER 500 VOLTS INPUT |
0 |
|
|
VTU-DIN | Module | Box | Active | AC/DC | Current Sensor | - | 1 | Ratiometric, 4mA ~ 20mA | - | 0Hz ~ 5kHz | - | ±1% | 24V | 500ms | - | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
AHR 1000 B420TRANSDUCER 1000A 4-20MA |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.