Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
20310509101SENSOR CURRENT HALL 500A AC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Voltage | - | - | ±0.1% | ±1% | 15V ~ 24V | 1µs | 35mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
IVT-S-2K5-U0-I-CAN2-12/24CURRENT SENSOR - ISA-SCALE IVT-S |
0 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 2500A | - | - | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 600-TTRANSDUCER |
0 |
|
|
LTC | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±1.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CTL2001FSENSOR CURRENT 100A, 150A, 200A |
0 |
|
|
CTL | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 100A, 150A, 200A (Selectable) | 1 | Ratiometric, 0V ~ 10V | - | 50Hz ~ 60Hz | - | ±1% | Self Powered | 100ms | - | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
AK 5 B420LTRANSDUCER |
0 |
|
|
AK | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 2A, 5A (Selectable) | 1 | Current | - | 20Hz ~ 100Hz | - | ±1% | 24V | 300ms | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
CSNM191-005SENSOR CURRENT HALL 1000A AC/DC |
0 |
|
|
CSN | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±12V ~ 18V | 1µs | 14mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LA 10-I/SP8SENSORS |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR4150-75SENSOR CURRENT XFMR 75A AC |
0 |
|
|
CR4100 | Module, Dual Pass Through | Bulk | Obsolete | AC | Transformer w/Conditioning | 75A | 2 | Ratiometric, 0V ~ 5V | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 75mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
LT 1005-S/SP3TRANSDUCER |
0 |
|
|
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.4% | ±15V | 1µs | - | -25°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 505-S/SP3TRANSDUCER |
0 |
|
|
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CRD4110-25SENSOR CURRENT XFMR 25A AC |
0 |
|
|
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 25A | 1 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CRD4110-15SENSOR CURRENT XFMR 15A AC |
0 |
|
|
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 15A | 1 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CRD4110-5SENSOR CURRENT XFMR 5A AC |
0 |
|
|
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 1 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CRD4110-1SENSOR CURRENT XFMR 1A AC |
0 |
|
|
CRD4100 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1A | 1 | RS485 | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 30mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4460-0.5SENSOR CURRENT XFMR 0.5A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 500mA | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 90mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
PCM 30-PTRANSDUCER |
0 |
|
|
PCM | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 30A | 1 | Current | - | DC ~ 1kHz | ±0.2% | ±1% | 24V | 30µs | 50mA | -25°C ~ 55°C | - | - | Unidirectional | Through Hole | - |
|
AHR 1000 B5TRANSDUCER |
0 |
|
|
AHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Analog Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 35mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
AHR 1000 B10TRANSDUCER |
0 |
|
|
AHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Analog Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 35mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
AHR 2000 B10TRANSDUCER |
0 |
|
|
AHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 2000A | 1 | Analog Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 35mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
AHR 1500 B420TRANSDUCER |
0 |
|
|
AHR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1500A | 1 | Voltage | - | DC, 20Hz ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.