Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
LA 205-S/SP33SENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Current | - | DC ~ 100kHz | ±1% | ±0.6% | ±15V | 500ns | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2010-S/SP28TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | 0.2mA/A | 150kHz | ±0.1% | ±0.3% | 14.25V ~ 25.2V | 500ns | 48mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 2010-S/SPA1TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
ENCORE (4A)TRANSDUCER CURRENT SENS SHUNT 4A |
0 |
|
|
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 4A | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -25°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (5A)TRANSDUCER CURRENT SENS SHUNT 5A |
0 |
|
|
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 5A | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | 8ns | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (500MA 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
|
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 500mA | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (4A 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
|
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 4A | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (1MA 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
|
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 1mA | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (300MA 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
|
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 300mA | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (2A 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
|
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 2A | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (2MA 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
|
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 2mA | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (3A 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
|
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 3A | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (200MA 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
|
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 200mA | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (3MA 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
|
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 3mA | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
ENCORE (5A 100MV)VERY HIGH PERFORMANCE SHUNT |
0 |
|
|
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 50A | 1 | Open Collector | - | 40kHz | - | ±0.2% | - | - | - | -35°C ~ 70°C | - | - | - | Free Hanging | - |
|
DK 300 B10TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
DK 400 B10TRANSDUCER |
0 |
|
|
DK | Module, Single Pass Through | Bulk | Active | DC | Current Transducer | 200A, 300A, 400A (Selectable) | 1 | Voltage | - | DC | ±0.75% | ±2% | 20V ~ 50V | 100ms | 100mA | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
DK 200 B10TRANSDUCER |
0 |
|
|
DK | Module, Single Pass Through | Bulk | Active | DC | Hall Effect, Open Loop | 100A, 150A, 200A (Selectable) | 1 | Voltage | - | DC | ±0.75% | ±2% | 20V ~ 45V | 100ms | 100mA | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
DK 400 B5TRANSDUCER |
0 |
|
|
DK | Module, Single Pass Through | Bulk | Active | DC | Current Transducer | 200A, 300A, 400A (Selectable) | 1 | Analog Voltage | - | DC | ±0.75% | ±2% | 20V ~ 50V | 300ms | 100mA | -20°C ~ 50°C | - | - | - | Chassis Mount | - |
|
CTSS0000SENSOR CURRENT SWITCH 150A AC |
0 |
|
|
CTS | Module, Single Pass Through | Bulk | Active | AC | Current Switch | 150A | 1 | SSR | - | 6Hz ~ 100Hz | - | - | Self Powered | 120ms | 150mA | -50°C ~ 65°C | - | - | Bidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.