Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CAB-SF 1500-001TRANSDUCER |
0 |
|
|
CAB | Module, Single Pass Through | Bulk | Active | DC | Flux Gate | 1500A | 1 | CAN Bus | - | DC ~ 20Hz | ±0.1% | ±0.5% | 9V ~ 16V | - | 1.4A | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CAB-SF 1500-002TRANSDUCER |
0 |
|
|
CAB | Module, Single Pass Through | Bulk | Active | DC | Flux Gate | 1500A | 1 | CAN Bus | - | DC ~ 20Hz | ±0.1% | ±0.5% | 9V ~ 16V | - | 1.4A | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LAC 300-S/SP7SENSORS |
0 |
|
|
LAC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 400A | 1 | Current | - | DC ~ 50kHz | ±1.2% | ±0.4% | ±15V | - | - | -40°C ~ 75°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 200-S/SP1TRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.5% | ±15V ~ 24V | 1µs | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
HAX 3000-STRANSDUCER |
0 |
|
|
HAX | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 3000A | 1 | Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
20310200101SENSOR CURRENT HALL 200A AC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.8% | 15V | 1µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1010-S/SPA3TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 1000A | 1 | Current | 0.2mA/A | DC ~ 200kHz | ±0.15% | ±0.4% | ±25.2V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1010-S/SP28TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 510-S/SP22TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 500A | 1 | Current | 0.28mA/A | 200kHz | ±0.1% | ±0.6% | 14.25V ~ 25.2V | 500ns | 49mA (Typ) | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
HTR 200-SB/SP1TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 306-S/SP1TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HAC 800-S/SP22TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LTC 350-STRANSDUCER |
0 |
|
|
LTC | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 350A | 1 | - | - | DC ~ 100kHz | ±0.1% | ±0.5% | 15V ~ 24V | 1µs | 35mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 350-S/SP5TRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 350A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.5% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HTR 400-SBTRANSDUCER |
0 |
|
|
HTR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Analog Voltage | - | DC ~ 10kHz | ±1% | ±2% | 12V ~ 15V | 10µs | 20mA | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
HOP 500-SBTRANSDUCER |
0 |
|
|
HOP | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Analog Voltage | - | DC ~ 8kHz | ±1% | ±2% | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
HOP 600-SBTRANSDUCER |
0 |
|
|
HOP | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Analog Voltage | - | DC ~ 8kHz | ±1% | ±2% | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
HOP 300-SBTRANSDUCER |
0 |
|
|
HOP | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Analog Voltage | - | DC ~ 8kHz | ±1% | ±2% | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
HOP 400-SBTRANSDUCER |
0 |
|
|
HOP | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Analog Voltage | - | DC ~ 8kHz | ±1% | ±2% | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CR4411-40RMS AC CURRENT TRANSDUCER 0-40A |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.