Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HAR 1000-STRANSDUCER |
0 |
|
|
HAR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Analog Voltage | - | DC ~ 10kHz | ±0.5% | ±0.5% | 15V | 5µs | 20mA | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
HAXC 1500-STRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CT 0.1-TPSENSOR CURRENT FLUX 100MA AC/DC |
0 |
|
|
CT | Module | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 100mA | 1 | Ratiometric, Voltage | - | DC ~ 7kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CT 0.2-TPSENSOR CURRENT FLUX 200MA AC/DC |
0 |
|
|
CT | Module | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 200mA | 1 | Ratiometric, Voltage | - | DC ~ 11kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CT 0.4-TPSENSOR CURRENT FLUX 400MA AC/DC |
0 |
|
|
CT | Module | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 400mA | 1 | Ratiometric, Voltage | - | DC ~ 18kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HAX 1500-S/SP20TRANSDUCER |
0 |
|
|
HAX | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1500A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 310-S/SPA0TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±11.4V ~ 21V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 510-S/SPA4TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 500A | 1 | Current | 0.2mA/A | DC ~ 200kHz | ±0.1% | ±0.6% | ±14.25V ~ 25.2V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 310-S/SP20TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 300A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±21V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
AP 400 B420LTRANSDUCER |
0 |
|
|
AP | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 200A, 300A, 400A (Selectable) | 1 | Current | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 12V ~ 24V | 150ms | - | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
AP 100 B420LTRANSDUCER |
0 |
|
|
AP | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 50A, 75A, 100A (Selectable) | 1 | Current | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 12V ~ 24V | 150ms | - | -20°C ~ 60°C | - | - | - | Chassis Mount | - |
|
AP 200 B420LTRANSDUCER |
0 |
|
|
AP | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 100A, 150A, 200A (Selectable) | 1 | Current | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 12V ~ 24V | 150ms | - | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
AP 50 B420LTRANSDUCER |
0 |
|
|
AP | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 10A, 25A, 50A (Selectable) | 1 | Current | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 12V ~ 24V | 150ms | - | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
ART-B22-D125/SP25CURR SENSE XFMR FLEXIBLE COIL |
0 |
|
|
ART | Module | Bulk | Active | AC | Rogowski Coil | 2000A | 1 | Voltage | 0.0225mV/A | 420kHz | - | - | - | - | - | -40°C ~ 80°C | - | - | - | Chassis Mount | - |
|
HAL 750-S/SP1TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 210-S/SP5TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 100A | 1 | Current | 1mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±15.75V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
|
20310500101SENSOR CURRENT HALL 500A AC |
1 |
|
|
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.6% | 15V ~ 24V | 1µs | 24mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
|
20310200102SENSOR CURRENT HALL 200A AC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.8% | 12V ~ 15V | 1µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
LA 305-S/SP5SENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Current | - | DC ~ 100kHz | ±1% | ±0.8% | ±12V ~ 15V | 500ns | - | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1010-S/SP16TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.