Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
CSLA1ELSENSOR CURRENT HALL 625A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 625A | 1 | Ratiometric, Voltage | 5.6mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LF 510-S/SPA5TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 500A | 1 | Current | 0.2mA/A | DC ~ 200kHz | ±0.1% | ±0.6% | ±14.25V ~ 25.2V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
SSA-100SENSOR CURRENT ISOLATED 100A |
0 |
|
|
SSA | Module | Bulk | Obsolete | DC | Shunt | 100A | 1 | Ratiometric, Voltage | - | 300kHz | ±0.1% | ±0.1% | 3V ~ 5.5V | 1.6µs | 40mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
ART-B22-D125/SP4CURR SENSE XFMR FLEXIBLE COIL |
0 |
|
|
ART | Module | Bulk | Active | AC | Rogowski Coil | 1000A | 1 | - | - | 50Hz/60Hz | - | ±0.5% | - | - | - | -40°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
LA 205-S/SP1SENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 200A | 1 | - | - | DC ~ 100kHz | ±0.1% | ±0.8% | 12V ~ 15V | 1µs | 20mA | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
S42S1T0D24ZMCURRENT SENSOR (1000A; 24V; 5000 |
0 |
|
|
S42S D24 | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Current | - | DC ~ 250kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 500ns | 45mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 310-S/SP15TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±11.4V ~ 21V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 305-S/SP15TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 510-S/SP5TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 500A | 1 | Current | 0.2mA/A | DC ~ 200kHz | ±0.1% | ±0.6% | ±14.25V ~ 25.2V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 310-S/SP16CLOSED LOOP HALL EFFECT |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 505-S/SP38TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CT 0.2-PSENSOR CURRENT FLUX 200MA AC/DC |
0 |
|
|
CT | Module | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 200mA | 1 | Ratiometric, Voltage | - | DC ~ 11kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LF 510-S/SPA3TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 310-S/SPA1TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±11.4V ~ 21V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 510-S/SP34TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 500A | 1 | Current | 0.2mA/A | DC ~ 200kHz | ±0.1% | ±0.6% | ±14.25V ~ 25.2V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 305-S/SP9TRANSDUCER |
0 |
|
|
LF | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 20V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HAX 1200-STRANSDUCER |
0 |
|
|
HAX | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 1200A | 1 | Analog Voltage | - | DC ~ 25kHz | ±1% | ±1% | 15V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CSNS300M-002S300 AMPS CURRENT SENSOR 4PIN INV |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
AP 50 B10TRANSDUCER |
0 |
|
|
AP | Module | Bulk | Active | AC/DC | Current Transducer | 10A, 25A, 50A (Selectable) | 1 | Analog Voltage | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 22.8V ~ 25.2V | 150ms | 30mA | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
AP 400 B10TRANSDUCER |
0 |
|
|
AP | Module | Bulk | Active | AC/DC | Current Transducer | 200A, 300A, 400A (Selectable) | 1 | Analog Voltage | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 22.8V ~ 25.2V | 150ms | 30mA | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.