Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
L51S2T5D15CMCURRENT SENSOR (2500A; 15V) -40 |
0 |
|
|
L51S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 2500A | 1 | Ratiometric, Voltage and Current | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 18V | 5µs | 30mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L51S1T5D15CJCURRENT SENSOR (1500A; 15V) -40 |
0 |
|
|
L51S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1500A | 1 | Ratiometric, Voltage and Current | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 18V | 5µs | 30mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L51S1T2D15CJCURRENT SENSOR (1200A; 15V) -40 |
0 |
|
|
L51S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1200A | 1 | Ratiometric, Voltage and Current | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 18V | 5µs | 30mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L51S600D15CMCURRENT SENSOR (600A; 15V) -40 |
0 |
|
|
L51S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage and Current | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 18V | 5µs | 30mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L51S1T5D15CMCURRENT SENSOR (1500A; 15V) -40 |
0 |
|
|
L51S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1500A | 1 | Ratiometric, Voltage and Current | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 18V | 5µs | 30mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L51S500D15CMCURRENT SENSOR (500A; 15V) -40 |
0 |
|
|
L51S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage and Current | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 18V | 5µs | 30mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L51S1T0D15CMCURRENT SENSOR (1000A; 15V) -40 |
0 |
|
|
L51S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Ratiometric, Voltage and Current | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 18V | 5µs | 30mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
CT 0.1-PSENSOR CURRENT FLUX 200MA AC/DC |
0 |
|
|
CT | Module | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 200mA | 1 | Ratiometric, Voltage | - | DC ~ 7kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HTA 500-S/SP2TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
SRCN-C290-110 CHANNELS AC CURRENT SENSOR RS |
0 |
|
|
SRCN | Module | Bag | Active | AC/DC | Current Sensor | 5A | 10 | RS485 | - | - | - | ±2.5% | 23.5V ~ 24.5V | - | 60mA | 0°C ~ 65°C | - | - | Bidirectional | DIN Rail | - |
|
LAC 300-S/SP8SENSORS |
0 |
|
|
LAC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Current | - | DC ~ 50kHz | ±1% | ±0.5% | ±24V | - | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 310-S/SP6TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 310-S/SP14TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±11.4V ~ 21V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CAB-SF 500-C/SP1-000TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CAB-SF 500-C/SP1-001TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CAB-SF 500-C/SP1-002TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LT 508-S6TRANSDUCER |
0 |
|
|
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.4% | ±15V ~ 18V | 1µs | - | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
HTA 1000-S/SP16SENSOR CURRENT HALL 1000A AC/DC |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CT 0.4-PSENSOR CURRENT FLUX 400MA AC/DC |
0 |
|
|
CT | Module | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 400mA | 1 | Ratiometric, Voltage | - | DC ~ 18kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HAT 2184-S/SP6TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.
