Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SSA-250SENSOR CURRENT ISOLATED 250A |
0 |
|
|
SSA | Module | Bulk | Obsolete | DC | Shunt | 250A | 1 | Ratiometric, Voltage | - | 300kHz | ±0.1% | ±0.1% | 3V ~ 5.5V | 1.6µs | 40mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 210-S/SP3TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 100A | 1 | Current | 1mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±15.75V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 200-P/SP12SENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
AT 10 B5TRANSDUCER |
0 |
|
|
AT | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 10A | 1 | Voltage | - | 50Hz/60Hz | ±0.5% | ±1.5% | - | 300ms | - | -20°C ~ 60°C | - | - | - | Chassis Mount | - |
|
LF 205-P/SP1TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HTA 500-S/SP7TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HTA 200-SSENSOR CURR 200A -/+15V MOD |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HAH3DR 660-S07/SP2TRANSDUCER |
0 |
|
|
HAH3DR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 660A | 1 | Voltage | 3.030mV/A | DC ~ 40kHz | ±0.5% | - | 4.9V ~ 5.1V | 6µs | 60mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
HTA 400-SSENSOR CURRENT HALL 400A AC/DC |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
SSA-500SENSOR CURRENT ISOLATED 500A |
0 |
|
|
SSA | Module | Bulk | Obsolete | DC | Shunt | 500A | 1 | Ratiometric, Voltage | - | 300kHz | ±0.1% | ±0.1% | 3V ~ 5.5V | 1.6µs | 40mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 210-S/SP1TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 200A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.02% | ±0.2% | ±15.75V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HAC 500-STRANSDUCER |
0 |
|
|
HAC | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect | 500A | 1 | Voltage | - | DC ~ 50kHz | ±1% | ±1% | 15V | 7µs | 25mA | -10°C ~ 80°C | - | - | - | Chassis Mount | - |
|
HAC 265-S/SP10TRANSDUCER |
0 |
|
|
HAC | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Current Transducer | 265A | 1 | Current | - | - | ±1% | ±1% | ±15V | 10µs | - | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 200-P/SP10SENSORS |
0 |
|
|
LA200-P | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Current | - | DC ~ 100kHz | ±0.15% | ±0.65% | ±12V ~ 15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
|
CSLA2DHSENSOR CURRENT HALL 235A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 235A | 1 | Ratiometric, Voltage | 9.8mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HAL 160-S/SP2TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LT 308-S7/SP13TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CSNV1500N-156CSNV1500 SERIES HALL-EFFECT CURR |
0 |
|
|
CSNV1500 | Module, Single Pass Through | Box | Active | AC/DC | Hall Effect, Closed Loop | 1500A | 1 | CAN Bus | - | - | - | ±1% | 7V ~ 18V | - | 200mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CSNV1500N-356CSNV1500 SERIES HALL-EFFECT CURR |
0 |
|
|
CSNV1500 | Module, Single Pass Through | Box | Active | AC/DC | Hall Effect, Closed Loop | 1500A | 1 | CAN Bus | - | - | - | ±1% | 7V ~ 18V | - | 200mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CSNV1500N-326CSNV1500 SERIES HALL-EFFECT CURR |
0 |
|
|
CSNV1500 | Module, Single Pass Through | Box | Active | AC/DC | Hall Effect, Closed Loop | 1500A | 1 | CAN Bus | - | - | - | ±1% | 7V ~ 18V | - | 200mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.