Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HTC 1500-S/SP4TRANSDUCER |
0 |
|
|
HTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1500A | 1 | Analog Voltage | - | DC ~ 10kHz | ±1% | ±1% | ±15V | 10µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CSNS300M-001CURRENT SENSORS |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LTC 350-SFTRANSDUCER |
0 |
|
|
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 350A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.5% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LV 25-1000/SP2SENSORS |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LA 205-S/SP6SENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
* | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CSNS300M-500CURRENT SENSORS |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CAB-SF 1500-003TRANSDUCER |
0 |
|
|
CAB | Module, Single Pass Through | Bulk | Active | DC | Flux Gate | 1500A | 1 | CAN Bus | - | DC ~ 20Hz | ±0.1% | ±0.5% | 9V ~ 16V | - | 1.4A | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CR4410S-0.5SENSOR CURRENT XFMR 0.5A AC |
0 |
|
|
CR4400 | Module | Bulk | Discontinued at Digi-Key | AC | Transformer w/Conditioning | 500mA | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 40mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4450-0.5SENSOR CURRENT XFMR 0.5A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 500mA | 2 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 75mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
HAX 5000-STRANSDUCER |
0 |
|
|
HAX | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 5000A | 1 | Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1010-S/SP36TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | 0.2mA/A | DC ~ 200kHz | ±0.15% | ±0.4% | ±14.25V ~ 25.2V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HTC 2000-S/SP2TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR5210-50SPLIT CORE CURRENT TRANSDUCER |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR5210-150DC CURRENT TRANSDUCER |
0 |
|
|
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LTC 500-STRANSDUCER |
0 |
|
|
LTC | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | - | - | DC ~ 100kHz | ±0.1% | ±0.5% | 15V ~ 24V | 1µs | 35mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 500-S/SP3TRANSDUCER |
0 |
|
|
LTC | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 500-S/SP5TRANSDUCER |
0 |
|
|
LTC | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CSSV1500N-152D1500A ASIL C CURRENT SENSOR |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR4211-10SENSOR CURRENT XFMR 10A AC |
0 |
|
|
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 10A | 1 | Ratiometric, 0V ~ 10V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4211-50SENSOR CURRENT XFMR 50A AC |
0 |
|
|
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 50A | 1 | Ratiometric, 0V ~ 10V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.