Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CR4211-70SENSOR CURRENT XFMR 70A AC |
0 |
|
|
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 70A | 1 | Ratiometric, 0V ~ 10V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4211-100SENSOR CURRENT XFMR 100A AC |
0 |
|
|
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 100A | 1 | Ratiometric, 0V ~ 10V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4211-5SENSOR CURRENT XFMR 5A AC |
0 |
|
|
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 1 | Ratiometric, 0V ~ 10V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4211-200SENSOR CURRENT XFMR 200A AC |
0 |
|
|
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 200A | 1 | Ratiometric, 0V ~ 10V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4211-2SENSOR CURRENT XFMR 2A AC |
0 |
|
|
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 2A | 1 | Ratiometric, 0V ~ 10V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4211-150SENSOR CURRENT XFMR 150A AC |
0 |
|
|
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 150A | 1 | Ratiometric, 0V ~ 10V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4211-20SENSOR CURRENT XFMR 20A AC |
0 |
|
|
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 20A | 1 | Ratiometric, 0V ~ 10V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
HTC 1000-S/SP2TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
ARH-B22-D70TRANSDUCER |
0 |
|
|
ARH | Module | Bulk | Active | AC | Rogowski Coil | 2000A | 1 | Voltage | 0.0225mV/A | 1.15MHz | - | - | - | - | - | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LF 505-S/SP36TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 1010-S/SPA6TRANSDUCER |
0 |
|
|
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 1188A | 1 | Current | 0.333mA/A | DC ~ 200kHz | ±0.15% | ±0.4% | ±25.2V | 500ns | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CR4420-30SENSOR CURRENT XFMR 30A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 30A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 45mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4420-100SENSOR CURRENT XFMR 100A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 100A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 45mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4420-25SENSOR CURRENT XFMR 25A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 25A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 45mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4420-20SENSOR CURRENT XFMR 20A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 20A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 45mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4420-150SENSOR CURRENT XFMR 150A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 150A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 45mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4420-10SENSOR CURRENT XFMR 10A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 10A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 45mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4420-15SENSOR CURRENT XFMR 15A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 15A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 45mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4420-40SENSOR CURRENT XFMR 40A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 40A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 45mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4420-5SENSOR CURRENT XFMR 5A AC |
0 |
|
|
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 45mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.