Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
L40S1T2D15JCURRENT SENSOR (1200A; 15V) -40 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 1200A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
CSLA1GFSENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 29.7mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CTSR 0.6-TP/SP2SENSOR CURRENT FLUX 600MA AC/DC |
0 |
|
|
CTSR | Module | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 600mA | 1 | Ratiometric, Voltage | - | 9.5kHz | ±0.4% | ±1.5% | 4.75V ~ 5.25V | 30µs | 21.6mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
CSCA0300A000B15B01SENSOR CURRENT HALL 300A AC/DC |
0 |
|
|
CSCA-A | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | ±15V | 3µs | 17mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S500D15CMCURRENT SENSOR (500A; 15V) -40 1 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S500D15CJCURRENT SENSOR (500A; 15V) -40 1 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S600D15CJCURRENT SENSOR (600A; 15V) -40 1 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S600D15CMCURRENT SENSOR (600A; 15V) -40 1 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
|
CSLA1DJSENSOR CURRENT HALL 225A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 225A | 1 | Ratiometric, Voltage | 13.2mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L40S800D15CMCURRENT SENSOR (800A; 15V) -40 1 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 800A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S800D15CJCURRENT SENSOR (800A; 15V) -40 1 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 800A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
CSCA0600A000B15B01SENSOR CURRENT HALL 600A AC/DC |
0 |
|
|
CSCA-A | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | ±15V | 3µs | 17mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
CSCA0400A000B15B01SENSOR CURRENT HALL 400A AC/DC |
0 |
|
|
CSCA-A | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | ±15V | 3µs | 17mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
CSNE151-006SENSOR CURRENT HALL 36A AC/DC |
0 |
|
|
CSN | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 36A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
LESR 6-NP KIT3 PIECE KIT SENSOR CURRENT HALL |
0 |
|
|
LESR | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 23mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LESR 15-NP KIT3 PIECE KIT SENSOR CURRENT HALL |
0 |
|
|
LESR | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 27.5mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LESR 25-NP KIT3 PIECE KIT SENSOR CURRENT HALL |
0 |
|
|
LESR | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 32.5mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LESR 50-NP KIT3 PIECE KIT SENSOR CURRENT HALL |
0 |
|
|
LESR | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 51.3mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LKSR 6-NP KIT3 PIECE KIT SENSOR CURRENT HALL |
0 |
|
|
LKSR | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 23mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LKSR 15-NP KIT3 PIECE KIT SENSOR CURRENT HALL |
0 |
|
|
LKSR | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 27.5mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.