Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CTSR 1-TP/SP19TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
L40S1T2D15CMCURRENT SENSOR (1200A; 15V) -40 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 1200A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S1T2D15CJCURRENT SENSOR (1200A; 15V) -40 |
0 |
|
|
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 1200A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 100-TP/SP2SENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Current | - | DC ~ 200kHz | ±0.15% | ±0.7% | ±12V ~ 15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 100-TP/SP7SENSORS |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LA 100-TP/SP10SENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Current | - | DC ~ 200kHz | ±0.15% | ±0.7% | ±12V ~ 15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
|
CSLA2GESENSOR CURRENT HALL 92A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 92A | 1 | Ratiometric, Voltage | 26.1mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LPSR 6-NP KIT3 PIECE KIT SENSOR CURRENT HALL |
0 |
|
|
LPSR | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 23mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LPSR 15-NP KIT3 PIECE KIT SENSOR CURRENT HALL |
0 |
|
|
LPSR | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 27.5mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LPSR 25-NP KIT3 PIECE KIT SENSOR CURRENT HALL |
0 |
|
|
LPSR | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 32.5mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LPSR 50-NP KIT3 PIECE KIT SENSOR CURRENT HALL |
0 |
|
|
LPSR | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 51.3mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
CSNR161-004SENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
CSN | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±12V ~ 15V | 0.5µs | 14mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LA 25-NP/SP39SENSORS |
0 |
|
|
LA | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 2A | 1 | Current | - | DC ~ 150kHz | ±0.7% | ±0.5% | ±15V | - | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LA 25-NP/SP38SENSORS |
0 |
|
|
LA | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 400mA | 1 | Current | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LA 25-NP/SP34SENSORS |
0 |
|
|
LA | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1.5A | 1 | Current | - | DC ~ 150kHz | ±0.2% | ±0.6% | ±15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
|
CSLA2DESENSOR CURRENT HALL 92A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 92A | 1 | Ratiometric, Voltage | 25.6mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CSNR151-004SENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
CSN | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±12V ~ 15V | 0.5µs | 14mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HAC 179-S/SP10TRANSDUCER |
0 |
|
|
HAC | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 179A | 1 | Voltage | - | - | ±1% | ±1% | ±15V | 10µs | - | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
CSNR151-002SENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
CSN | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Current | - | - | - | ±0.5% | ±12V ~ 15V | 0.5µs | 14mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
|
CSLA2GDSENSOR CURRENT HALL 72A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 72A | 1 | Ratiometric, Voltage | 32.7mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.