| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CR9421-ACASENSOR CURRENT SWITCH 100A AC |
0 |
|
|
CR9400 | Module, Single Pass Through | Bulk | Active | AC | Current Switch | 100A | 1 | SCR | - | 50Hz ~ 400Hz | - | - | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | - | - | Bidirectional | - | - |
|
CR9550-10-MSENSOR CURRENT XFMR 10A AC |
0 |
|
|
CR9500 | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 10A | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | - | - | Bidirectional | - | - |
|
CR9380-NPN-MSENSOR CURRENT SWITCH 100A NPN |
0 |
|
|
CR9380 | Module, Single Pass Through | Bulk | Active | AC | Current Switch | 100A | 1 | NPN | - | 50Hz ~ 400Hz | - | - | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | - | - | Bidirectional | - | - |
|
CR9380-ACA-MSENSOR CURRENT SWITCH 100A SCR |
0 |
|
|
CR9380 | Module, Single Pass Through | Bulk | Active | AC | Current Switch | 100A | 1 | SCR | - | 50Hz ~ 400Hz | - | - | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | - | - | Bidirectional | - | - |
|
CR9580-50-MSENSOR CURRENT XFMR 50A AC |
0 |
|
|
CR9500 | Hinged Ring, 0.40" Dia, Wire Leads | Bulk | Active | AC | Transformer w/Conditioning | 50A | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | - | - | Bidirectional | - | - |
|
CR9350-PNP-MSENSOR CURRENT SWITCH 100A PNP |
0 |
|
|
CR9300 | Module, Single Pass Through | Bulk | Active | AC | Current Switch | 100A | 1 | PNP | - | 50Hz ~ 400Hz | - | - | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | - | - | Bidirectional | - | - |
|
CR9350-NPN-MSENSOR CURRENT SWITCH 100A NPN |
0 |
|
|
CR9300 | Module, Single Pass Through | Bulk | Active | AC | Current Switch | 100A | 1 | NPN | - | 50Hz ~ 400Hz | - | - | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | - | - | Bidirectional | - | - |
|
CR9580-20-MSENSOR CURRENT XFMR 20A AC |
0 |
|
|
CR9500 | Hinged Ring, 0.40" Dia, Wire Leads | Bulk | Active | AC | Transformer w/Conditioning | 20A | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | - | - | Bidirectional | - | - |
|
CR9350-ACA-MSENSOR CURRENT SWITCH 100A SCR |
0 |
|
|
CR9300 | Module, Single Pass Through | Bulk | Active | AC | Current Switch | 100A | 1 | SCR | - | 50Hz ~ 400Hz | - | - | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | - | - | Bidirectional | - | - |
|
CR9550-20SENSOR CURRENT XFMR 20A AC |
0 |
|
|
CR9500 | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 20A | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 100ms (On), 250ms (Off) | - | -30°C ~ 60°C | - | - | Bidirectional | - | - |
|
LA 55-P/SP21SENSORS |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
|
CSLA1CFSENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 29.7mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CSDD1EGSENSOR CURRENT SWITCH 10A AC/DC |
0 |
|
|
CSD | 5-DIP Module | Bulk | Obsolete | AC/DC | Current Switch | 10A | 1 | NPN | - | - | - | - | 4.5V ~ 24V | 100µs | 22mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CSLA2CDSENSOR CURRENT HALL 72A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 72A | 1 | Ratiometric, Voltage | 32.7mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CTSR 0.6-TP/SP18TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CTSR 1.5-TP/SP18TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CTSR 1-TP/SP18TRANSDUCER |
0 |
|
|
CTSR | Module | Bulk | Active | AC/DC | Closed Loop | 1A | 1 | Voltage | 1.2V/A | DC ~ 9.5kHz | ±0.4% | - | 4.75V ~ 5.25V | 30µs | 21.6mA | -40°C ~ 105°C | - | - | - | Through Hole | - |
|
|
CSNB121SENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
CSN | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.1% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
CSLA1DESENSOR CURRENT HALL 75A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 75A | 1 | Ratiometric, Voltage | 39.1mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CTSR 3-TP/SP19TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.