Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CTSR 0.6-P/SP10TRANSDUCER |
0 |
|
|
CTSR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 600mA | 1 | Voltage | 2.476V/A | DC ~ 9.5kHz | ±0.4% | ±1.5% | 4.75V ~ 5.25V | 30µs | 17.5A | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
CTSR 1-PTRANSDUCER |
0 |
|
|
CTSR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1A | 1 | Voltage | 1.2V/A | DC ~ 9.5kHz | ±0.5% | ±1.9% | 4.75V ~ 5.25V | 50µs | 21.6A | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
CTSR 1-P/SP10TRANSDUCER |
0 |
|
|
CTSR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1A | 1 | Voltage | 1.2V/A | DC ~ 9.5kHz | ±0.5% | ±1.9% | 4.75V ~ 5.25V | 50µs | 21.6A | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
|
CSLA2CESENSOR CURRENT HALL 62A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 92A | 1 | Ratiometric, Voltage | 26.1mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LA 25-NP/SP25CURRENT TRANSDUCER 25A |
0 |
|
|
LA | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Current | - | DC ~ 150kHz | ±0.2% | ±1% | ±15V | 1µs | - | -40°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
LXSR 15-NPS KIT3 PIECE KIT SENSOR CURRENT HALL |
1 |
|
|
LXSR | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 27.5mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HAS 500-S/SP56SENSORS |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CSDA1ACSENSOR CURRENT SWITCH 7.5A AC/DC |
0 |
|
|
CSDA | Module | Bulk | Obsolete | AC/DC | Current Switch | 7.5A | 1 | NPN | - | - | - | ±0.5% | 6V ~ 16V | 100µs | 12mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HASS 316-S/SPH00SENSORS |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HC2F100-SNSENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
HC2F | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 20mV/A | 20kHz | ±0.2% | - | 4.75V ~ 5.25V | 15µs | 20mA | -40°C ~ 125°C | - | - | Bidirectional | Through Hole | - |
|
S27S300D15YSENSOR CURRENT HALL 300A AC/DC |
0 |
|
|
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.4% | ±12V ~ 20V | 1µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
|
CSDA1DASENSOR CURRENT SWITCH 1A AC/DC |
0 |
|
|
CSDA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Current Switch | 1A | 1 | NPN | - | - | - | ±0.5% | 6V ~ 16V | 100µs | 12mA | -25°C ~ 85°C | - | - | Bidirectional | Connector | - |
|
T60404N4641X921DIFFERENTIAL CURRENT SENSOR FOR |
0 |
|
|
- | Module | Box | Active | AC/DC | Flux Gate | 32A, 40A | 1 | Open Collector | - | DC ~ 2kHz | - | - | 4.8V ~ 5.2V | - | 45mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
LA 25-NP/SP11SENSORS |
0 |
|
|
LA | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1A | 1 | - | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
LA 25-NP/SP13SENSORS |
0 |
|
|
LA | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500mA | 1 | - | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | 1µs | 10mA | -40°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
LA 25-NP/SP9SENSORS |
0 |
|
|
LA | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1.5A | 1 | Current | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | 1µs | - | 0°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
HAS 200-S/SP16SENSORS |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR45-B-MCURRENT INDICATOR, BLUE, W/ MOUN |
0 |
|
|
- | - | Bag | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR45-W-MCURRENT INDICATOR, WHITE, W/ MOU |
0 |
|
|
- | - | Bag | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LT 58-S7/SP12TRANSDUCER |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.