Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CR45-Y-MCURRENT INDICATOR, YELLOW, W/ MO |
0 |
|
|
- | - | Bag | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR45-A-MCURRENT INDICATOR, AMBER, W/ MOU |
0 |
|
|
- | - | Bag | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CSCA0600A000B15B02SENSOR CURRENT HALL 600A AC/DC |
0 |
|
|
CSCA-A | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | ±15V | 3µs | 17mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
CSCA0300A000B15B02SENSOR CURRENT HALL 300A AC/DC |
0 |
|
|
CSCA-A | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | ±15V | 3µs | 17mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
HAS 500-S/SP58SENSORS |
0 |
|
|
HAS | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 500A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | 15V | 3µs | 15mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 55-P/SP23SENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Current | - | DC ~ 200kHz | ±0.15% | ±0.7% | ±12V ~ 15V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HOYS 200-S/SP32-0100Linear IC |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CSCA0500A000B15B02SENSOR CURRENT HALL 500A AC/DC |
0 |
|
|
CSCA-A | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | ±15V | 3µs | 17mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
CSCA0400A000B15B02SENSOR CURRENT HALL 400A AC/DC |
0 |
|
|
CSCA-A | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | ±15V | 3µs | 17mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
CSNE151-202SENSOR CURRENT HALL 90A AC/DC |
0 |
|
|
CSN | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 90A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
|
CSLA1CESENSOR CURRENT HALL 75A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 75A | 1 | Ratiometric, Voltage | 39.4mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CSNB131SENSOR CURRENT HALL 100A AC/DC |
0 |
|
|
CSN | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.1% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
CR45-WSENSOR CURRENT INDICATOR 100A AC |
0 |
|
|
CR45 | Module | Bulk | Active | AC | Current Indicator | 100A | 1 | LED | 2A | 50Hz ~ 1kHz | - | - | Self Powered | - | - | -10°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
ATO-75-B1I-D10TRANSDUCER |
0 |
|
|
ATO | Module, Single Pass Through | Bulk | Active | AC/DC | Current Transducer | 75A | 1 | Current | - | 500kHz | ±0.1% | ±3% | - | - | - | -30°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
CS0550BLCURRENT SENSOR,OPEN LOOP,5A,+/-5 |
3 |
|
|
CSXX50BL | Module | Tray | Active | AC | Open Loop | 5A | 1 | Ratiometric, Voltage | - | DC ~ 55kHz | ±0.5% | ±4.9% | ±4.75V ~ 5.25V | 7µs | 25mA | -10°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
HOYS 550-S/SPH00-0100Linear IC |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOYS 432-S/SPH00-0100Linear IC |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOYS 372-S/SPH00-0100Linear IC |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOYS 520-S/SPH00-0100Linear IC |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOYS 486-S/SPH00-0100Linear IC |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.