Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HSNBV-D05TRANSDUCER |
0 |
|
|
HSNBV-D05 | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A, 400A (Selectable) | 1 | Ratiometric, Voltage | 5mV/A | DC ~ 1.1kHz | ±0.5% | ±3% | 4.75V ~ 5.25V | 10µs | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
HSNBV-D09TRANSDUCER |
0 |
|
|
HSNBV-D09 | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A, 500A (Selectable) | 1 | Ratiometric, Voltage | 4mV/A | DC ~ 1.1kHz | ±0.5% | ±3% | 4.75V ~ 5.25V | 10µs | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
HSNBV-D10TRANSDUCER |
0 |
|
|
HSNBV-D10 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600A | 2 | Voltage | 10mV/A | DC ~ 1.1kHz | ±0.5% | - | 4.75V ~ 5.25V | - | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
HSNBV-D06TRANSDUCER |
0 |
|
|
HSNBV-D06 | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A, 300A (Selectable) | 1 | Ratiometric, Voltage | 6.67mV/A | DC ~ 1.1kHz | ±0.5% | ±3% | 4.75V ~ 5.25V | 10µs | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
HSNBV-D01TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
|
L34S200D15SENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
L34SXXXD15 | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | ±15V | 5µs | 25mA | -30°C ~ 80°C | - | - | Bidirectional | Panel Mount | - |
|
|
L34S300D15SENSOR CURRENT HALL 300A AC/DC |
0 |
|
|
L34SXXXD15 | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | ±15V | 5µs | 25mA | -30°C ~ 80°C | - | - | Bidirectional | Panel Mount | - |
|
LA 25-NP/SP43SENSORS |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LAS 100-TPSENSORS |
0 |
|
|
LAS | Module | Bulk | Not For New Designs | AC/DC | Current Transducer | 100A | 1 | Analog Voltage | - | DC ~ 100kHz | ±0.7% | ±1% | 5V | 500ns | 18mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
|
L34S400D15SENSOR CURRENT HALL 400A AC/DC |
0 |
|
|
L34SXXXD15 | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | ±15V | 5µs | 25mA | -30°C ~ 80°C | - | - | Bidirectional | Panel Mount | - |
|
CDSR 0.07-NPDTTRANSDUCER |
0 |
|
|
CDSR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 70A | 1 | Voltage | 8.79V/A | DC ~ 2kHz | - | ±1% | 3.26V ~ 3.33V | 1ms | 50mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LAS 50-TP/SP4SENSORS |
0 |
|
|
LAS | Module | Bulk | Not For New Designs | AC/DC | Closed Loop | 50A | 1 | Analog Voltage | - | DC ~ 100kHz | 0.7% | ±1% | 5V | 500ns | 18mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
CDSR 0.07-TPDTTRANSDUCER |
0 |
|
|
CDSR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 70A | 1 | Voltage | 8.79V/A | DC ~ 2kHz | - | ±1% | 3.26V ~ 3.33V | 1ms | 50mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CSCA0200A000B15B02SENSOR CURRENT HALL 200A AC/DC |
0 |
|
|
CSCA-A | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | ±15V | 3µs | 17mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
|
L34S500D15SENSOR CURRENT HALL 500A AC/DC |
0 |
|
|
L34SXXXD15 | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | ±15V | 5µs | 25mA | -30°C ~ 80°C | - | - | Bidirectional | Panel Mount | - |
|
|
CSLA1DGSENSOR CURRENT HALL 120A AC/DC |
0 |
|
|
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 120A | 1 | Ratiometric, Voltage | 24.6mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
|
L34S600D15SENSOR CURRENT HALL 600A AC/DC |
0 |
|
|
L34SXXXD15 | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | ±15V | 5µs | 25mA | -30°C ~ 80°C | - | - | Bidirectional | Panel Mount | - |
|
HY 30-PSENSOR CURRENT HALL 30A AC/DC |
0 |
|
|
HY | Module | Tray | Obsolete | AC/DC | Hall Effect, Open Loop | 30A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 10mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
CSCA0050A000B15B02SENSOR CURRENT HALL 50A AC/DC |
0 |
|
|
CSCA-A | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±2% | ±15V | 3µs | 17mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 100-P/SP13SENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Current | - | DC ~ 200kHz | ±0.15% | ±0.7% | ±12V ~ 15V | 1µs | - | -25°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.