Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HAH1DRW 900-S/SP6TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HAH1DRW 900-S/SP5TRANSDUCER |
0 |
|
|
HAH1DRW | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 900A | 1 | Ratiometric, Voltage | 2.22mV/A | DC ~ 40kHz | ±1% | ±3.25% | 4.75V ~ 5.25V | 6µs | 25mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
HAH1DRW 600-S/SP6TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HAH1DRW 600-S/SP5TRANSDUCER |
0 |
|
|
HAH1DRW | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Voltage | 3.33mV/A | DC ~ 40kHz | ±1% | - | 4.75V ~ 5.25V | 6µs | 25mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
HAH1DRW 800-S/SP4TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HAH1DRW 700-S/SP5TRANSDUCER |
0 |
|
|
HAH1DRW | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 700A | 1 | Ratiometric, Voltage | 2.85mV/A | DC ~ 40kHz | ±1% | ±3.25% | 4.75V ~ 5.25V | 6µs | 25mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
LA 130-P/SP1SENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 130A | 1 | Current | - | DC ~ 150kHz | ±1% | ±0.5% | ±12V ~ 15V | 300ns | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
F26P050S05AFLUX-GATE CS VREFOUT (50A; +5V |
0 |
|
|
F26P | Module, Single Pass Through | Tray | Active | AC/DC | Flux Gate, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | DC ~ 100kHz | ±1% | ±0.96% | 4.75V ~ 5.25V | 1µs | 20mA | -40°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
S21S180D15JNSENSOR CURRENT HALL 180A DC |
0 |
|
|
- | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 180A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.3% | ±1% | ±12V | 1µs | 16mA | -30°C ~ 80°C | - | - | Bidirectional | Panel Mount | - |
|
|
CSNE151-104SENSOR CURRENT HALL 56A AC/DC |
0 |
|
|
CSN | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 56A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
HO 100-SW-0400SENSORS |
0 |
|
|
HO | Module, Single Pass Through | Bulk | Active | AC/DC | Open Loop | 100A | 1 | Voltage | - | DC ~ 20kHz | ±0.6% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HO 150-SW-0400SENSORS |
0 |
|
|
HO | Module, Single Pass Through | Bulk | Active | AC/DC | Open Loop | 150A | 1 | Voltage | - | DC ~ 20kHz | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HO 200-SW-0100SENSORS |
0 |
|
|
HO | Module, Single Pass Through | Bulk | Active | AC/DC | Open Loop | 200A | 1 | Voltage | - | DC ~ 20kHz | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HO 100-SW-0100SENSORS |
0 |
|
|
HO | Module, Single Pass Through | Bulk | Active | AC/DC | Open Loop | 100A | 1 | Voltage | - | DC ~ 20kHz | ±0.6% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HO 150-SW-0100SENSORS |
0 |
|
|
HO | Module, Single Pass Through | Bulk | Active | AC/DC | Open Loop | 150A | 1 | Voltage | - | DC ~ 20kHz | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HO 250-SW-0100SENSORS |
0 |
|
|
HO | Module, Single Pass Through | Bulk | Active | AC/DC | Open Loop | 250A | 1 | Voltage | - | DC ~ 20kHz | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L34S300D15TCURRENT SENSOR (300A; 15V) |
0 |
|
|
L34S D15T | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.5% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
LA 55-P/SP1SENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 50A | 1 | - | - | DC ~ 200kHz | ±0.15% | ±0.9% | 12V ~ 15V | 1µs | 10mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
F26P100S05AFLUX-GATE CS VREFOUT (100A; +5 |
0 |
|
|
F26P | Module, Single Pass Through | Tray | Active | AC/DC | Flux Gate, Closed Loop | 100A | 1 | Ratiometric, Voltage | 6.25mV/A | DC ~ 100kHz | ±1% | ±0.96% | 4.75V ~ 5.25V | 1µs | 20mA | -40°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
HTB 300-P/SP11TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.