| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HX 04-P/SP31SENSORS |
0 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 4A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1.5% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HTFS 400-P/SP2SENSOR CURRENT 400A 5V MOD |
0 |
|
|
HTFS | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 240kHz | ±0.5% | 1% | 4.75V ~ 5.25V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HAH1BV S/D24TRANSDUCER |
0 |
|
|
HAH1BV | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | -600A ~ 300A | 1 | Voltage | 16mV/A | DC ~ 140Hz | ±0.5% | - | 4.75V ~ 5.25V | 10ms | 21mA | -40°C ~ 70°C | - | - | Unidirectional | Chassis Mount | - |
|
HAH1BV S/32TRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LAH 100-P/SP3SENSORS |
0 |
|
|
LAH | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Current | - | DC ~ 200kHz | ±0.15% | ±0.25% | ±15V | 500ns | - | -25°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
HAIS 300-P/SP2SENSORS |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HAIS 100-P/SP2SENSORS |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LA 100-P/SP50SENSORS |
0 |
|
|
LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Current | - | DC ~ 200kHz | ±0.15% | ±0.7% | ±12V ~ 15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HAIS 400-P/SP2SENSORS |
0 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
F26P050S05FLUX-GATE CS VREFOUT (50A; +5V |
0 |
|
|
F26P | Module, Single Pass Through | Tray | Active | AC/DC | Flux Gate, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | DC ~ 100kHz | ±1% | ±0.96% | 4.75V ~ 5.25V | 600ns | 19mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HOF 150-PWTRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOF 200-PWTRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOF 100-PWTRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOF 80-PWTRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOF 540-PWTRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOF 250-PWTRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOF 50-PWTRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOF 270-PWTRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOF 400-PWTRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HOF 300-PWTRANSDUCER |
0 |
|
|
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.