Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RC05-300-1000-STRANSF CURR SENSE 300MV/KA 50HZ |
62 |
|
|
RC05-SSSS-LLLL-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 8000A | 1 | - | 0.3mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Free Hanging | - |
|
HAL 500-SSENSOR CURRENT HALL 500A AC/DC |
41 |
|
|
HAL | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 500A | 1 | Voltage | - | DC ~ 50kHz | ±0.5% | ±1% | ±15V | 3µs | 25mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
RC05-450-1000-STRANSF CURR SENSE 450MV/KA 50HZ |
54 |
|
|
RC05-SSSS-LLLL-O | Module, Single Pass Through | Box | Active | AC/DC | Rogowski Coil | 8000A | 1 | - | 0.45mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Free Hanging | - |
|
CSNV1500N-324CSNV1500 SERIES HALL-EFFECT CURR |
50 |
|
|
CSNV1500 | Module, Single Pass Through | Box | Active | AC/DC | Hall Effect, Closed Loop | 1500A | 1 | CAN Bus | - | - | - | ±1% | 7V ~ 18V | - | 200mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CSNV1500N-124CSNV1500 SERIES HALL-EFFECT CURR |
50 |
|
|
CSNV1500 | Module, Single Pass Through | Box | Active | AC/DC | Hall Effect, Closed Loop | 1500A | 1 | CAN Bus | - | - | - | ±1% | 7V ~ 18V | - | 200mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CSNV1500N-154CSNV1500 SERIES HALL-EFFECT CURR |
48 |
|
|
CSNV1500 | Module, Single Pass Through | Box | Active | AC/DC | Hall Effect, Closed Loop | 1500A | 1 | CAN Bus | - | - | - | ±1% | 7V ~ 18V | - | 200mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
AT 150 B10SENSOR CURRENT XFMR 150A AC |
64 |
|
|
AT | Module | Bulk | Active | AC | Transformer w/Conditioning | 150A | 1 | Ratiometric, 0V ~ 10V | - | 50/60Hz | ±0.5% | ±1.5% | Self Powered | 300ms | - | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
CSSV1500N-154CSSV1500N SERIES CLOSED LOOP CUR |
48 |
|
|
CSSV1500 | Module, Single Pass Through | Box | Active | AC/DC | Current Sensor | 1500A | 1 | CAN Bus | - | DC, 50Hz ~ 60Hz | - | ±0.5% | 6V ~ 18V | - | 200mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CAB-SF 500-CTRANSDUCER |
138 |
|
|
CAB | Module, Single Pass Through | Bulk | Active | DC | Flux Gate | 500A | 1 | - | - | DC ~ 100Hz | ±0.1% | ±0.5% | 8.5V ~ 16V | - | 200mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
AT 100 B5SENSOR CURRENT XFMR 100A AC |
68 |
|
|
AT | Module | Bulk | Active | AC | Transformer w/Conditioning | 100A | 1 | Ratiometric, 0V ~ 5V | - | 50/60Hz | ±0.5% | ±1.5% | Self Powered | 300ms | - | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
APR 400 B10SENSOR CURRENT 200A, 300A, 400A |
40 |
|
|
APR | Module | Bulk | Active | AC | Transformer w/Conditioning | 200A, 300A, 400A (Selectable) | 1 | Ratiometric, Voltage (Selectable) | - | 30Hz ~ 6kHz | ±0.5% | ±1% | 24V | 400ms | 30mA | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
AT 50 B420LSENSOR CURRENT XFMR 50A AC |
118 |
|
|
AT | Module | Bulk | Active | AC | Transformer w/Conditioning | 50A | 1 | Ratiometric, 4mA ~ 20mA | - | 50/60Hz | ±0.5% | ±1.5% | 20V ~ 30V | 100ms | 30mA | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
LF205-SCUR TRANSDUCER, CLO LOOP,2000A |
139 |
|
|
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
SSD-100A-RSHUNT CUR 100A 24BIT ISOL RS-485 |
38 |
|
|
SSD | Module | Bag | Active | DC | Current Sensor | 100A | 1 | RS485 | - | DC ~ 5kHz | ±0.1% | ±0.1% | 5V ~ 60V | - | 55mA (Typ) | -40°C ~ 115°C | - | - | Bidirectional | Chassis Mount | - |
|
SSD-1000A-R1000A 24BIT ISOLATED SHUNT CUR |
49 |
|
|
SSD | Module | Bulk | Active | DC | Current Sensor | 1000A | 1 | RS485 | - | - | ±0.1% | ±0.1% | 24V ~ 60V | - | 55mA (Typ) | -40°C ~ 115°C | - | - | Bidirectional | Chassis Mount | - |
|
SSD-250A-R100A - 24BIT ISOLATED SHUNT CUR |
36 |
|
|
SSD | Module | Bulk | Active | DC | Current Sensor | 250A | 1 | RS485 | - | - | ±0.1% | ±0.1% | 5V ~ 60V | - | 55mA (Typ) | -40°C ~ 115°C | - | - | Bidirectional | Chassis Mount | - |
|
ICD-A-500-CAN1-12CURRENT SENSOR - ISA-SCALE DC CO |
48 |
|
|
ICD | Module | Tray | Active | DC | Shunt | 500A | 1 | CAN Bus | - | - | ±0.1% | ±0.8% | 5.5V ~ 26V | - | 50mA | -40°C ~ 105°C | Automotive | - | Bidirectional | Chassis Mount | - |
|
KIT - IVT-S-500-U0-I-CAN2-12/24 W/ CONNECTORKIT - IVT-S-500-U0-I-CAN2-12/24 |
36 |
|
|
IVT-S | Module | Tray | Active | DC | Shunt | 500A | 1 | - | - | - | 0.01% | ±0.4% | 5.5V ~ 40V | - | 80mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
CT110PDV-ID6XTREMESENSE HIGH LINEARITY, HIGH |
2,953 |
|
|
XtremeSense™ Crocus | 6-TDFN Exposed Pad | Tape & Reel (TR) | Last Time Buy | AC/DC | Magnetoresistive | 10A | 1 | Ratiometric, Voltage and Current | 200mV/A | DC ~ 200kHz | ±0.15% | ±0.5% | 2.7V ~ 5.5V | 20µs | 2.5mA | -40°C ~ 85°C | - | - | Bidirectional | Surface Mount | 6-DFN (3x3) |
|
CT110RDV-ID6XTREMESENSE HIGH LINEARITY, HIGH |
856 |
|
|
XtremeSense™ Crocus | 6-TDFN Exposed Pad | Tape & Reel (TR) | Last Time Buy | AC/DC | Magnetoresistive | 15A | 1 | Ratiometric, Voltage and Current | 40mV/mT | DC ~ 200kHz | ±0.15% | ±0.5% | 2.7V ~ 5.5V | 20µs | 2.5mA | -40°C ~ 85°C | - | - | Bidirectional | Surface Mount | 6-DFN (3x3) |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.