| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FG-R04-4BASENSOR CURRENT FLUX 40A IEC VRT |
147 |
|
|
FG | Module | Box | Active | AC/DC | Flux Gate, Open Loop | 50mA | 1 | Ratiometric, Voltage | 40V/A | DC ~ 55Hz | - | - | 4.75V ~ 5.25V | 250ms (AC), 1s (DC) | 13mA (Typ) | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
FG-R05-4BASENSOR CURRENT FLUX 40A IEC VRT |
110 |
|
|
FG | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Open Loop | 50mA | 1 | Ratiometric, Voltage | 40V/A | DC ~ 55Hz | - | - | 4.75V ~ 5.25V | 250ms (AC), 1s (DC) | 13mA (Typ) | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LZSR 200-TP/SP1CLOSED-LOOP CURRENT SENSOR 200A |
136 |
|
|
LZSR-TP/SP1 | Module | Bulk | Active | AC/DC | Closed Loop | 200A | 1 | Voltage | 3.125mV/A | DC ~ 200kHz | ±0.18% | - | 4.75V ~ 5.25V | - | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
RCM01-02RESIDUAL CURRENT MONITOR, 6MA DC |
320 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | 50Hz/60Hz | - | - | 10.8V ~ 13.2V | - | 14.5mA | -40°C ~ 85°C | - | - | - | Through Hole | - |
|
RCM14-03_SYS_HRCM14-03 SYSTEM, CONSISTS OF 901 |
560 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | 50Hz/60Hz | - | - | 10.8V ~ 13.2V | - | 14.5mA | -40°C ~ 85°C | - | - | - | Through Hole | - |
|
RCM14-01_SYS_HRCM14-01 SYSTEM, CONSISTS OF 901 |
560 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | 50Hz/60Hz | - | - | 10.8V ~ 13.2V | - | 14.5mA | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
RCM14-01_SYS_VRCM14-01 SYSTEM, CONSISTS OF 901 |
560 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | 50Hz/60Hz | - | - | 10.8V ~ 13.2V | - | 14.5mA | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
RCM14-03RESIDUAL CURRENT MONITOR, 6MA DC |
155 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | DC ~ 60Hz | - | - | 10.8V ~ 13.2V | - | 40mA | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
RCM14-03_SYS_VRCM14-03 SYSTEM, CONSISTS OF 901 |
555 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | DC ~ 60Hz | - | - | 10.8V ~ 13.2V | - | 40mA | -40°C ~ 85°C | - | - | - | Through Hole | - |
|
HCSP-1BS-0900AUTOMOTIVE OPEN LOOP CURRENT SEN |
106 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 900A | 1 | Ratiometric, Voltage | 2.22mV/A | 70kHz ~ 250kHz | - | - | 4.5V ~ 5.5V | 3µs | 14mA | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
|
RCM20-03RESIDUAL CURRENT MONITOR, 6MA DC |
185 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | 50Hz/60Hz | - | - | 10.8V ~ 13.2V | - | 14.5mA | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
RCM20-01RESIDUAL CURRENT MONITOR, 6MA DC |
182 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 6mA | 1 | - | - | 50Hz/60Hz | - | - | 12V ~ 24V | - | 13mA | -40°C ~ 85°C | - | - | - | Chassis Mount | - |
|
HAH3DR 800-S0ETRANSDUCER |
69 |
|
|
HAH3DR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 800A | 1 | Ratiometric, Voltage | 2.5mV/A | DC ~ 40kHz | ±1% | ±3.5% | 4.75V ~ 5.25V | 6µs | 60mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
CSNV500M-125CSNV500 SERIES HALL-BASED CLOSED |
56 |
|
|
CSNV500 | Module | Box | Active | AC/DC | Hall Effect, Closed Loop | 25A | 3 | CAN Bus | - | DC ~ 200kHz | ±0.1% | ±0.24% | 4.75V ~ 5.25V | 200ns | 12mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
CSNV500M-124CSNV500 SERIES HALL-BASED CLOSED |
54 |
|
|
CSNV500 | Module | Box | Active | AC/DC | Hall Effect, Closed Loop | 25A | 3 | CAN Bus | - | DC ~ 200kHz | ±0.1% | ±0.24% | 4.75V ~ 5.25V | 200ns | 12mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
CSNV500N-154CSNV500 SERIES HALL-BASED CLOSED |
36 |
|
|
CSNV500 | Module | Box | Active | AC/DC | Hall Effect, Closed Loop | 25A | 3 | CAN Bus | - | DC ~ 200kHz | ±0.1% | ±0.24% | 4.75V ~ 5.25V | 200ns | 12mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
CSNV500M-354MCSNV500 SERIES HALL-BASED CLOSED |
40 |
|
|
CSNV500 | Module, Single Pass Through | Box | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | CAN Bus | - | - | ±0.1% | ±0.5% | 7V ~ 18V | - | 250mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
RCM14-04_SYSRCM14-04 SYSTEM, CONSISTS OF 901 |
547 |
|
|
- | Module, Single Pass Through | Tray | Active | DC | Current Sensor | 56mA | 1 | - | - | DC ~ 60Hz | - | - | 12V ~ 24V | - | 25mA | -40°C ~ 85°C | - | - | - | Through Hole | - |
|
RC05-150-1000-STRANSF CURR SENSE 150MV/KA 50HZ |
48 |
|
|
RC05-SSSS-LLLL-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 8000A | 1 | - | 0.15mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Free Hanging | - |
|
HAC 200-SSENSOR CURRENT HALL 200A AC/DC |
40 |
|
|
HAC | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 7µs | 18mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.