Stromsensoren
| Foto | Herst.-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung/Gehäuse | Verpackung | Produktstatus | Zur Messung | Sensortyp | Strom - Erfassung | Anzahl der Kanäle | Ausgang | Empfindlichkeit | Frequenz | Linearität | Genauigkeit | Spannung - Versorgung | Reaktionszeit | Strom - Versorgung (Max) | Betriebstemperatur | Klasse | Qualifizierung | Polarisation | Montageart | Lieferant Gerätepaket |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HO 60-NP-0100SENSOR CURRENT HALL 60A AC/DC |
879 |
|
|
HO-NP | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 60A | 1 | Ratiometric, Voltage | - | DC ~ 350kHz | ±0.5% | ±1.4% | 5V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
|
F02P050S05LSENSOR |
400 |
|
|
F02P | Module | Tray | Active | AC | Flux Gate, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | 300kHz | ±1% | ±0.9% | 5V | 0.3µs | 55mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
L01Z300S05SENSOR CURRENT HALL 300A AC/DC |
152 |
|
|
- | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 10µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
LKSR 6-NPSENSOR CURRENT HALL 6A UNIPOLAR |
383 |
|
|
LKSR | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 23mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LKSR 15-NPSENSOR CURRENT HALL 15A UNIPOLAR |
373 |
|
|
LKSR | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 27.5mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LPSR 15-NPSENSOR CURRENT HALL 15A UNIPOLAR |
236 |
|
|
LPSR | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 27.5mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LPSR 6-NPSENSOR CURRENT HALL 6A UNIPOLAR |
173 |
|
|
LPSR | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.2mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 23mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HX 25-PSENSOR CURRENT HALL 25A AC/DC |
300 |
|
|
HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 25A | 1 | Ratiometric, Voltage | - | 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LES 50-NPSENSOR CURRENT HALL 50A UNIPOLAR |
164 |
|
|
LES | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | 300kHz | ±0.1% | ±2.25% | 4.75V ~ 5.25V | 400ns | 45mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LPSR 50-NPSENSOR CURRENT HALL 50A UNIPOLAR |
198 |
|
|
LPSR | Module | Tray | Active | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | 300kHz | ±0.1% | ±1.25% | 4.75V ~ 5.25V | 400ns | 51.3mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 75-P1 MHZ OPEN-LOOP CURRENT SENSOR 7 |
297 |
|
|
HOB-P | Module | Bulk | Active | AC/DC | Open Loop | 75A | 1 | Voltage | 10.667mV/A | 1MHz | ±0.6% | - | 4.6V ~ 5.5V | 200ns | 26mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 100-P/SP331 MHZ OPEN-LOOP CURRENT SENSOR 1 |
139 |
|
|
HOB-P/SP33 | Module | Bulk | Active | AC/DC | Open Loop | 100A | 1 | Voltage | 4.6mV/A | 1MHz | ±0.5% | - | 3.14V ~ 3.46V | - | 24mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 130-P/SP11 MHZ OPEN-LOOP CURRENT SENSOR 1 |
119 |
|
|
HOB-P/SP1 | Module | Bulk | Active | AC/DC | Open Loop | 130A | 1 | Voltage | 16mV/A | 1MHz | ±0.45% | - | 4.6V ~ 5.5V | - | 26mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 100-P1 MHZ OPEN-LOOP CURRENT SENSOR 1 |
106 |
|
|
HOB-P | Module | Bulk | Active | AC/DC | Open Loop | 100A | 1 | Voltage | 8mV/A | 1MHz | ±0.5% | - | 4.6V ~ 5.5V | 200ns | 26mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
LA37S400S05KMCURRENT SENSOR (400A; 5V) -40 10 |
199 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 400A | 1 | Analog Voltage | 1.563mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 3.5µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S500S05KMCURRENT SENSOR (500A; 5V) -40 10 |
190 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 500A | 1 | Analog Voltage | 1.25mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 3.5µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S200S05KMCURRENT SENSOR (200A; 5V) -40 10 |
164 |
|
|
LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 200A | 1 | Analog Voltage | 3.125mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 3.5µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
RCM SYSTEM CT VERTICALRCM14 SYSTEM CURRENT TRANSFORMER |
600 |
|
|
- | - | Tray | Active | - | - | 6mA | - | - | - | - | - | - | 12V | - | - | -40°C ~ 85°C | - | - | - | Through Hole | - |
|
RCM SYSTEM CT HORIZONTALRCM14 SYSTEM CURRENT TRANSFORMER |
350 |
|
|
- | - | Tray | Active | - | - | 6mA | - | - | - | - | - | - | 12V | - | - | -40°C ~ 85°C | - | - | - | Through Hole | - |
|
RC01-300TRANSF CURR SENSE 300MV/KA 50HZ |
134 |
|
|
RC01-SSS-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 200A | 1 | - | 0.3mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Through Hole | - |
Kategorieübersicht
Stromsensoren Produkte und Auswahlhilfe
Stromsensoren werden in Industrieautomation, Automobilelektronik, Kommunikationstechnik, Unterhaltungselektronik, erneuerbaren Energien und vielen weiteren elektronischen Systemen eingesetzt. Wir bieten Produkte verschiedener Hersteller, Gehäuseformen und Spezifikationen zur einfachen Auswahl und Beschaffung.
Filtern Sie Stromsensoren nach Hersteller, wichtigen Parametern, Verfügbarkeit und Datasheet. Wenn das gewünschte Modell nicht aufgeführt ist, senden Sie uns eine Anfrage. Wir unterstützen Sie bei Verfügbarkeit, Lieferzeit und möglichen Alternativen.
FAQ
Wie wähle ich den passenden Stromsensoren aus?
Prüfen Sie zuerst elektrische Parameter, Gehäuse, Betriebstemperatur, Einsatzbedingungen und Herstelleranforderungen. Danach können Verfügbarkeit und Lieferzeit verglichen werden.
Kann ich anhand des angezeigten Lagerbestands direkt bestellen?
Bestände können sich ändern. Für Projekt- oder Mengenbedarf empfehlen wir eine Anfrage zur Bestätigung von aktuellem Bestand, Preis und Lieferzeit.
Was kann ich tun, wenn die gewünschte Teilenummer nicht gelistet ist?
Senden Sie uns Teilenummer und benötigte Menge. Wir können schwer verfügbare Teile prüfen und passende Alternativen anhand der Spezifikationen vorschlagen.
Sind Datasheets und technische Unterlagen verfügbar?
Ja. Nutzen Sie die Datasheet-Links in der Produktliste. Falls Unterlagen fehlen, können Sie uns für eine zusätzliche Prüfung kontaktieren.